{"product_id":"kuaiqu-battery-test-power-supply-r-sps6050s-60v-50a-3000w-with-4-group-memory-for-battery-system-testing","title":"KUAIQU Battery Test Power Supply R-SPS6050S 60V 50A 3000W with 4-Group Memory for Battery System Testing","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/R-SPS-S_English_Manual.pdf?v=1776247824\" rel=\"noopener\" style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" target=\"_blank\"\u003e \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" fill=\"currentColor\" viewbox=\"0 0 16 16\" style=\"margin-right: 8px;\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1 class=\"heading-3 ace-line old-record-id-IP70f9v6UdPrMRcIqQwc1RCzn1c\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/12.png?v=1776150334\" alt=\"\"\u003e\u003c\/h1\u003e\n\u003ch1\u003eKUAIQU Battery Test Power Supply \u003c\/h1\u003e\n\u003ch1\u003eR-SPS6050S 60V 50A 3000W with 4-Group\u003c\/h1\u003e\n\u003ch1\u003eMemory for Battery System Testing\u003c\/h1\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003e0-60V Adjustable Output for Battery System Test Conditions\u003c\/h3\u003e\n\u003cp\u003eBattery system testing may require different DC voltage conditions when evaluating battery-related equipment and system components. The R-SPS6050S provides an adjustable \u003cstrong\u003e0-60V DC output\u003c\/strong\u003e, allowing engineers to establish selected voltage conditions within the power supply's rated range.\u003c\/p\u003e\n\u003cp\u003eThis flexibility is useful when a test procedure requires different DC supply levels for evaluating compatible battery system components, power interfaces, control electronics, and other equipment that operates within the specified voltage range.\u003c\/p\u003e\n\u003ch3\u003e50A Output Capacity for High-Current Battery Testing\u003c\/h3\u003e\n\u003cp\u003eBattery-related test equipment can require substantially more current than conventional electronic bench applications. With up to \u003cstrong\u003e50A output current and 3000W rated power\u003c\/strong\u003e, the R-SPS6050S provides a high-power DC source for compatible battery system test setups with higher current requirements.\u003c\/p\u003e\n\u003cp\u003eThe combination of adjustable voltage and high current capacity allows engineers to establish different power conditions without changing to a lower-capacity laboratory supply when the test demand increases within the rated operating range.\u003c\/p\u003e\n\u003ch3\u003eReal-Time Voltage, Current and Power Monitoring\u003c\/h3\u003e\n\u003cp\u003eBattery System Testing requires engineers to know the electrical conditions being applied to the test setup. The R-SPS6050S uses a \u003cstrong\u003e4-digit Voltage, Current and Power Display\u003c\/strong\u003e to provide direct visibility into the output condition.\u003c\/p\u003e\n\u003cp\u003eDuring testing, users can observe the displayed voltage, current, and power while the connected battery-related equipment operates. This makes it easier to identify changes in power demand and compare electrical conditions between different test configurations.\u003c\/p\u003e\n\u003ch3\u003e4-Group Memory for Repeated Battery Test Conditions\u003c\/h3\u003e\n\u003cp\u003eBattery System Testing may involve multiple predefined test conditions. The \u003cstrong\u003eM1-M4 4-Group Memory Function\u003c\/strong\u003e allows frequently used voltage and current settings to be stored for later recall.\u003c\/p\u003e\n\u003cp\u003eInstead of manually setting the same parameters every time, engineers can use the stored memory groups when repeating established test configurations. This is particularly useful for development benches where the same battery system test conditions are used repeatedly.\u003c\/p\u003e\n\u003ch3\u003ePrecision Encoder for Controlled Parameter Adjustment\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePrecision Encoder\u003c\/strong\u003e provides direct adjustment of voltage and current settings from the front panel. When a battery system or related component needs to be evaluated at different DC input conditions, the encoder allows the operator to change the configured parameters conveniently.\u003c\/p\u003e\n\u003cp\u003eThis is useful during development and verification work where engineers need to move between several selected voltage or current settings rather than operate at only one fixed power condition.\u003c\/p\u003e\n\u003ch3\u003eOutput ON\/OFF for Battery System Power-Up Testing\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOutput ON\/OFF\u003c\/strong\u003e function allows the operator to apply or remove the DC output while keeping the configured settings available.\u003c\/p\u003e\n\u003cp\u003eFor Battery System Testing, this can support repeated power-up and power-down verification of compatible test equipment and battery-related systems. Engineers can switch the output during different test steps without having to completely reconfigure the power supply each time.\u003c\/p\u003e\n\u003ch3\u003eOCP and OVP for Controlled Battery Test Setups\u003c\/h3\u003e\n\u003cp\u003eThe R-SPS6050S incorporates \u003cstrong\u003eOver Current Protection and Over Voltage Protection\u003c\/strong\u003e. These protection functions provide additional safeguards when adjustable DC power is applied to compatible battery system test equipment.\u003c\/p\u003e\n\u003cp\u003eFor higher-power testing, protection functions are especially useful when establishing test conditions or connecting equipment with different electrical requirements. OCP and OVP should be used as protection functions and do not replace the test procedure or external protection requirements of the battery system.\u003c\/p\u003e\n\u003ch3\u003eRear Output Connection for High-Current Test Wiring\u003c\/h3\u003e\n\u003cp\u003eThe R-SPS6050S provides a \u003cstrong\u003eBack Panel Output\u003c\/strong\u003e for high-current connections. The front output is limited to below 5A, while the rear output supports the full rated output capability.\u003c\/p\u003e\n\u003cp\u003eFor Battery System Testing applications requiring higher current, the rear terminals provide the appropriate connection point for the test setup. This allows the power supply to be connected to compatible battery system equipment using wiring suitable for the required current.\u003c\/p\u003e\n\u003ch3\u003ePanel Lock for Stable Test Configuration\u003c\/h3\u003e\n\u003cp\u003eOnce the required voltage and current have been established, accidental changes to the front-panel controls can affect test consistency. The \u003cstrong\u003ePanel Lock\u003c\/strong\u003e function helps prevent unintended parameter adjustments during testing.\u003c\/p\u003e\n\u003cp\u003eThis is useful when a battery system test needs to remain under a defined DC power condition for an extended evaluation or repeated verification procedure.\u003c\/p\u003e\n\u003ch3\u003eUSB, RS232 and RS485 Interfaces for Test Bench Integration\u003c\/h3\u003e\n\u003cp\u003eThe R-SPS6050S includes \u003cstrong\u003eUSB, RS232 and RS485 interfaces\u003c\/strong\u003e, providing several connection options for suitable engineering and laboratory test environments.\u003c\/p\u003e\n\u003cp\u003eThese interfaces allow the Battery Test Power Supply to be incorporated into compatible test-bench setups where the power supply needs to coexist with other equipment. The interfaces should not be interpreted as dedicated BMS communication or battery management functions.\u003c\/p\u003e\n\u003ch3\u003eBuzzer Mute for Laboratory Test Operation\u003c\/h3\u003e\n\u003cp\u003eThe encoder knob includes a \u003cstrong\u003eBuzzer\u003c\/strong\u003e function that can be muted. This provides additional operating convenience when engineers repeatedly adjust settings during battery system development, verification, and bench testing.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eBattery System Testing\u003c\/h3\u003e\n\u003cp\u003eThe R-SPS6050S provides adjustable DC power for compatible battery system test setups requiring up to \u003cstrong\u003e60V, 50A, and 3000W\u003c\/strong\u003e. Engineers can establish different supply conditions and observe the resulting voltage, current, and power during evaluation.\u003c\/p\u003e\n\u003ch3\u003eBattery System Power Input Evaluation\u003c\/h3\u003e\n\u003cp\u003eThe adjustable output can be used to establish selected DC input conditions for compatible battery-related equipment. Engineers can change the voltage and current settings according to the requirements of the specific test procedure and the rated limits of the equipment under test.\u003c\/p\u003e\n\u003ch3\u003eHigh-Current Battery Equipment Testing\u003c\/h3\u003e\n\u003cp\u003eFor battery-related equipment that requires higher DC current during evaluation, the \u003cstrong\u003e50A maximum output and 3000W power rating\u003c\/strong\u003e provide substantially greater capacity than lower-power bench supplies.\u003c\/p\u003e\n\u003cp\u003eThe rear output connection is suitable for high-current test wiring when the required test current exceeds the front output connection limit.\u003c\/p\u003e\n\u003ch3\u003eBattery System Startup and Shutdown Verification\u003c\/h3\u003e\n\u003cp\u003eThe Output ON\/OFF function can be used when a test procedure requires repeated application and removal of DC power. This can support startup, shutdown, restart, and power interruption verification of compatible battery system equipment.\u003c\/p\u003e\n\u003ch3\u003eBattery System Operating Condition Comparison\u003c\/h3\u003e\n\u003cp\u003eBattery system development may require evaluation under more than one selected DC supply condition. The 0-60V adjustable output and Precision Encoder allow engineers to change the configured power condition and compare the electrical response of the connected test equipment.\u003c\/p\u003e\n\u003ch3\u003eRepeated Battery Test Configuration\u003c\/h3\u003e\n\u003cp\u003eFor test procedures that use recurring voltage and current settings, the \u003cstrong\u003eM1-M4 Memory Function\u003c\/strong\u003e provides four groups for storing frequently used configurations.\u003c\/p\u003e\n\u003cp\u003eThis can reduce repeated manual adjustment when engineers perform the same Battery System Testing procedure across multiple test units or repeat a previously established verification condition.\u003c\/p\u003e\n\u003ch3\u003eBattery-Related Power Electronics Testing\u003c\/h3\u003e\n\u003cp\u003eBattery systems often work together with power conversion and electronic control equipment. Within its rated 0-60V, 0-50A, and 3000W output capability, the R-SPS6050S can provide adjustable DC power for compatible battery-related power electronics and control equipment during development and verification.\u003c\/p\u003e\n\u003ch3\u003eBattery Test Bench Integration\u003c\/h3\u003e\n\u003cp\u003eThe combination of high-power DC output, real-time electrical display, rear high-current output, memory settings, Panel Lock, and \u003cstrong\u003eUSB, RS232 and RS485 interfaces\u003c\/strong\u003e makes the R-SPS6050S suitable for integration into compatible laboratory and engineering battery test benches.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eQuality Check and Terms of Service:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e DC Power Supply ×1, Output Power Cord ×1, Input Power Cord ×1, User Manual ×1, Warranty Card ×1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCE \u0026amp; FCC Certification:\u003c\/strong\u003e The product has passed CE and FCC certification requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspection Before Shipment:\u003c\/strong\u003e The DC power supply and included accessories are inspected before shipment to help ensure product quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomer Support:\u003c\/strong\u003e Contact us with any questions, and our customer support team will respond within 24 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eR-SPS6050S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Power Adjustable DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e0-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e0-50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C-40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation, Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.1% + 10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation, Current\u003c\/td\u003e\n\u003ctd\u003e≤0.1% + 2.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation, Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.01% + 2.5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation, Current\u003c\/td\u003e\n\u003ctd\u003e≤0.1% + 2.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Resolution, Voltage\u003c\/td\u003e\n\u003ctd\u003e10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Resolution, Current\u003c\/td\u003e\n\u003ctd\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Resolution, Voltage\u003c\/td\u003e\n\u003ctd\u003e10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Resolution, Current\u003c\/td\u003e\n\u003ctd\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Accuracy, Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.05% + 10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Accuracy, Current\u003c\/td\u003e\n\u003ctd\u003e≤0.01% + 10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Accuracy, Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.05% + 10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Accuracy, Current\u003c\/td\u003e\n\u003ctd\u003e≤0.01% + 10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ripple\u003c\/td\u003e\n\u003ctd\u003e≤800mVp-p \/ ≤120mVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ripple\u003c\/td\u003e\n\u003ctd\u003e≤40mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time, No Load\u003c\/td\u003e\n\u003ctd\u003e≤100ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time, Full Load\u003c\/td\u003e\n\u003ctd\u003e≤150ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFall Time, No Load\u003c\/td\u003e\n\u003ctd\u003e≤15s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFall Time, Full Load\u003c\/td\u003e\n\u003ctd\u003e≤50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Response Time\u003c\/td\u003e\n\u003ctd\u003e≤20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-Digit Voltage, Current and Power Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Function\u003c\/td\u003e\n\u003ctd\u003eM1-M4, 4 Groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOCP, OVP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Control\u003c\/td\u003e\n\u003ctd\u003eOutput ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003eFront Output and Rear High-Current Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003eApprox. 35 × 27 × 10cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose KUAIQU R-SPS6050S?\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKUAIQU Battery Test Power Supply R-SPS6050S\u003c\/strong\u003e combines a \u003cstrong\u003e0-60V adjustable output, 0-50A maximum current, and 3000W rated power\u003c\/strong\u003e for battery system test environments that require more DC power capacity than conventional laboratory supplies.\u003c\/p\u003e\n\u003cp\u003eIts value for Battery System Testing comes from the combination of adjustable power and practical test-operation features. The \u003cstrong\u003e4-digit Voltage, Current and Power Display\u003c\/strong\u003e allows engineers to observe the electrical output during testing, while the \u003cstrong\u003ePrecision Encoder\u003c\/strong\u003e provides direct adjustment when different test conditions are required.\u003c\/p\u003e\n\u003cp\u003eFor repeated battery test procedures, the \u003cstrong\u003eM1-M4 4-Group Memory Function\u003c\/strong\u003e helps recall frequently used voltage and current settings. \u003cstrong\u003eOutput ON\/OFF\u003c\/strong\u003e supports repeated power application and removal, while \u003cstrong\u003ePanel Lock\u003c\/strong\u003e helps maintain an established test configuration.\u003c\/p\u003e\n\u003cp\u003eFor higher-current battery system setups, the \u003cstrong\u003erear high-current output\u003c\/strong\u003e provides a suitable connection point for the full rated output, while \u003cstrong\u003eOCP and OVP\u003c\/strong\u003e provide additional protection functions. The built-in \u003cstrong\u003eUSB, RS232 and RS485 interfaces\u003c\/strong\u003e also provide flexible connectivity for suitable laboratory and engineering test benches.\u003c\/p\u003e\n\u003cp\u003eWith its combination of \u003cstrong\u003ehigh-current output, adjustable DC power, 4-group memory, real-time electrical monitoring, protection functions, and high-current rear connection\u003c\/strong\u003e, the R-SPS6050S is a practical \u003cstrong\u003eBattery Test Power Supply for Battery System Testing, battery equipment evaluation, high-current battery testing, operating condition comparison, startup and shutdown verification, and repeated battery test procedures\u003c\/strong\u003e within its rated specifications.\u003c\/p\u003e","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"AC220V(±10%) \/ R-SPS6050S-R","offer_id":48008803582129,"sku":"R-SPS6050S-R-B-220V-1007-02","price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/KUAIQU_Battery_Test_Power_Supply_R-SPS6050S_60V_50A_3000W_with_4-Group_Memory_for_Battery_System_Testing-01.png?v=1791361013","url":"https:\/\/www.kuaiquinstrument.com\/products\/kuaiqu-battery-test-power-supply-r-sps6050s-60v-50a-3000w-with-4-group-memory-for-battery-system-testing","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}