{"product_id":"kuaiqu-0-60v-0-5a-300w-dc-bench-power-supply-spps-h605-regulated-dc-power-supply-for-telecom-power-system-testing","title":"KUAIQU 0-60V 0-5A 300W DC Bench Power Supply SPPS-H605 Regulated DC Power Supply for Telecom Power System Testing","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/General_format-English_Manual.pdf?v=1780391148\" rel=\"noopener\" style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" target=\"_blank\"\u003e \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" fill=\"currentColor\" viewbox=\"0 0 16 16\" style=\"margin-right: 8px;\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/12.png?v=1776150334\"\u003e\u003c\/h1\u003e\n\u003ch1\u003eKUAIQU 0-60V 0-5A 300W DC Bench\u003c\/h1\u003e\n\u003ch1\u003ePower Supply SPPS-H605 Regulated DC\u003c\/h1\u003e\n\u003ch1\u003ePower Supply for Telecom Power System\u003c\/h1\u003e\n\u003ch1\u003eTesting\u003c\/h1\u003e\n\u003cp\u003eThe KUAIQU SPPS-H605 is a 0-60V 0-5A 300W DC Bench Power Supply designed for Telecom Power System Testing and controlled DC power verification. With an adjustable 0-60V output range, up to 5A output current, and 300W rated power, it provides regulated DC power for testing compatible telecom power equipment, DC power modules, control circuits, and related components within its rated operating range. OVP and OCP functions provide dedicated protection functions during controlled testing, while the encoder knob, Output ON\/OFF control, voltage and current readback, and USB 5V\/2A output support practical bench testing workflows.\u003c\/p\u003e\n\u003cp\u003eFor Telecom Power System Testing, the SPPS-H605 can be adjusted to the required DC test voltage and current according to the equipment under test. Its 10mV voltage setting and readback resolution and 1mA current setting and readback resolution allow users to make controlled adjustments and monitor the displayed output during bench testing.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003e0-60V Adjustable Output for Telecom Power System Testing\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 provides a 0-60V adjustable voltage range, 0-5A adjustable current range, and 300W rated power. This range allows the DC Bench Power Supply to be configured for different DC test conditions required when evaluating compatible telecom power equipment and power modules.\u003c\/p\u003e\n\u003cp\u003eUsers can adjust the output voltage and current with the encoder knob according to the requirements of the device under test, provided the operating conditions remain within the rated 60V, 5A, and 300W output capability.\u003c\/p\u003e\n\u003ch3\u003eRegulated DC Power for Telecom Equipment Testing\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 provides adjustable and regulated DC output for controlled testing of compatible telecom power systems and DC-powered equipment. Its load regulation and line regulation specifications support stable output conditions when the input or connected load changes within the specified operating conditions.\u003c\/p\u003e\n\u003cp\u003eThis makes the Regulated DC Power Supply suitable for bench-based verification where a controlled DC source is required for equipment power-up and operating checks.\u003c\/p\u003e\n\u003ch3\u003eOVP Protection for Controlled Telecom Power Testing\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 includes an OVP Function for over-voltage protection. During Telecom Power System Testing, OVP provides an additional protection function when applying adjustable DC power to compatible equipment and power modules.\u003c\/p\u003e\n\u003cp\u003eUsers can incorporate OVP into controlled test procedures where the applied voltage needs to remain within an intended protection range.\u003c\/p\u003e\n\u003ch3\u003eOCP Function for DC Power Module Testing\u003c\/h3\u003e\n\u003cp\u003eThe built-in OCP Function provides over-current protection during DC power testing. This can be useful when testing compatible telecom power modules and DC-powered equipment where output current needs to be controlled as part of the test procedure.\u003c\/p\u003e\n\u003cp\u003eThe 0-5A adjustable current range also allows users to configure different current conditions within the power supply's rated output capability.\u003c\/p\u003e\n\u003ch3\u003eEncoder Knob Adjustment and Output ON\/OFF Control\u003c\/h3\u003e\n\u003cp\u003eThe encoder knob provides direct adjustment of the power supply settings, while the Output ON\/OFF function allows users to enable or disable the DC output during testing.\u003c\/p\u003e\n\u003cp\u003eFor repeated Telecom Power System Testing, these controls allow users to adjust test conditions and start or stop the DC output without repeatedly changing the basic test setup.\u003c\/p\u003e\n\u003ch3\u003eVoltage and Current Readback for Test Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 provides voltage and current setting and readback functions. Voltage setting and readback resolution is 10mV, while current setting and readback resolution is 1mA.\u003c\/p\u003e\n\u003cp\u003eThe voltage setting and readback accuracy is specified at ≤0.01%+15mV, and current setting and readback accuracy is specified at ≤0.01%+10mA. These specifications provide users with defined measurement performance for monitoring the DC output during telecom power testing.\u003c\/p\u003e\n\u003ch3\u003eUSB 5V\/2A Output and Adjustable Buzzer Setting\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 includes a 5V\/2A USB output for compatible USB-powered devices used alongside the main DC testing setup. The encoder knob also includes a buzzer function that can be set to mute according to the user's operating preference.\u003c\/p\u003e\n\u003cp\u003eThese functions provide additional operating convenience during bench-based Telecom Power System Testing while keeping the primary DC output function separate from the USB output.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTelecom Power System Testing\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 is designed for controlled DC power testing of compatible telecom power systems and related equipment. Its 0-60V adjustable output and 0-5A current range allow users to configure the DC test conditions required by the equipment under test within the 300W rated power limit.\u003c\/p\u003e\n\u003cp\u003eThe Regulated DC Power Supply can be used for controlled power-up, output verification, and operating checks of compatible telecom DC equipment.\u003c\/p\u003e\n\u003ch3\u003eTelecom Power Module Testing\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 can provide adjustable DC power for testing compatible telecom power modules. Users can configure the voltage and current according to the test requirements and monitor voltage and current readback during operation.\u003c\/p\u003e\n\u003cp\u003eOVP and OCP functions provide additional protection functions that can be incorporated into controlled power module testing procedures.\u003c\/p\u003e\n\u003ch3\u003eDC Power Equipment Verification\u003c\/h3\u003e\n\u003cp\u003eFor compatible telecom DC equipment, the SPPS-H605 provides an adjustable DC source for bench verification. The 0-60V voltage range allows users to configure the output for different test voltage requirements rather than being limited to a single fixed output voltage.\u003c\/p\u003e\n\u003cp\u003eThe Output ON\/OFF function also supports repeated power application and removal during verification procedures.\u003c\/p\u003e\n\u003ch3\u003eTelecom Control Circuit Testing\u003c\/h3\u003e\n\u003cp\u003eThe adjustable DC output can be used as a test source for compatible telecom control circuits and DC-powered components that operate within the supply's rated output range.\u003c\/p\u003e\n\u003cp\u003eThe encoder knob allows direct adjustment of the configured output, while voltage and current readback allows users to observe the displayed operating conditions during testing.\u003c\/p\u003e\n\u003ch3\u003eDC Power-Up and Operating Checks\u003c\/h3\u003e\n\u003cp\u003eThe SPPS-H605 can be used during controlled power-up and operating checks of compatible telecom equipment. Users can configure the required DC voltage and current before enabling the output and then monitor the voltage and current readback during operation.\u003c\/p\u003e\n\u003cp\u003eThe OVP and OCP functions provide additional protection functions for these controlled test procedures.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eQuality Check and Terms of Service:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEach KUAIQU SPPS-H605 DC Bench Power Supply is inspected before shipment to help ensure that the product and its basic functions meet the specified requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 × SPPS-H605 DC Bench Power Supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Output Test Lead\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × AC Power Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × User Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Warranty Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuality Assurance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCE \u0026amp; FCC Certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspection before shipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCustomer support within 24 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle Unit Size: 31×12.5×22cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle Unit Weight: 1.72KG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCarton Quantity: 8 Units per Carton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPPS-H605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSPPS-H OCP\/OVP Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRegulated DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e0-60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e0-5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0℃-40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Output\u003c\/td\u003e\n\u003ctd\u003e5V\/2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.3%+10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation Current\u003c\/td\u003e\n\u003ctd\u003e≤0.1%+2.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation Voltage\u003c\/td\u003e\n\u003ctd\u003e≤0.01%+2.5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation Current\u003c\/td\u003e\n\u003ctd\u003e≤0.1%+2.5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Setting Resolution\u003c\/td\u003e\n\u003ctd\u003e10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Setting Resolution\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Readback Resolution\u003c\/td\u003e\n\u003ctd\u003e10mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Readback Resolution\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Setting Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.01%+15mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Setting Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.01%+10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.01%+15mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.01%+10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003e≤200mVp-p \/ ≤20mVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Current\u003c\/td\u003e\n\u003ctd\u003e≤20mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Test Bandwidth\u003c\/td\u003e\n\u003ctd\u003e20Hz-20MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time No Load\u003c\/td\u003e\n\u003ctd\u003e≤200mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time Full Load\u003c\/td\u003e\n\u003ctd\u003e≤300mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFall Time No Load\u003c\/td\u003e\n\u003ctd\u003e≤20S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFall Time Full Load\u003c\/td\u003e\n\u003ctd\u003e≤300mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Response\u003c\/td\u003e\n\u003ctd\u003e≤200mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V (AC110V optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003eAbout 21×17×8cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003eAbout 1.3KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Size\u003c\/td\u003e\n\u003ctd\u003e31×12.5×22cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight\u003c\/td\u003e\n\u003ctd\u003e1.72KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarton Quantity\u003c\/td\u003e\n\u003ctd\u003e8 Units per Carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose KUAIQU SPPS-H605?\u003c\/h2\u003e\n\u003cp\u003eThe KUAIQU SPPS-H605 combines a 0-60V adjustable output, 0-5A current range, and 300W rated power in a compact DC Bench Power Supply for Telecom Power System Testing. Its adjustable output allows users to configure different DC test conditions, while OVP and OCP provide dedicated protection functions for controlled testing procedures.\u003c\/p\u003e\n\u003cp\u003eThe SPPS-H605 also provides encoder knob adjustment, Output ON\/OFF control, voltage and current setting and readback, 10mV voltage resolution, 1mA current resolution, and USB 5V\/2A output. With defined load regulation, line regulation, ripple, rise time, fall time, and dynamic response specifications, it provides a practical Regulated DC Power Supply for compatible telecom power equipment, DC power modules, control circuits, and related bench testing applications within its rated 60V, 5A, and 300W output capability.\u003c\/p\u003e","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"AC220V(±10%) \/ SPPS-H605","offer_id":47915768185009,"sku":"SPPS-H605-B-220V-0910-02","price":119.0,"currency_code":"USD","in_stock":true},{"title":"AC110V(±10%) \/ SPPS-H605","offer_id":47915768217777,"sku":"SPPS-H605-B-110V-0910-02","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/KUAIQU_0-60V_0-5A_300W_DC_Bench_Power_Supply_SPPS-H605_Regulated_DC_Power_Supply_for_Telecom_Power_System_Testing1.png?v=1789024765","url":"https:\/\/www.kuaiquinstrument.com\/products\/kuaiqu-0-60v-0-5a-300w-dc-bench-power-supply-spps-h605-regulated-dc-power-supply-for-telecom-power-system-testing","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}