{"product_id":"industrial-control-equipment-testing-with-5-20kva-adjustable-ac-power-source-0-300v-45-400hz","title":"Industrial Control Equipment Testing with 5-20kVA Adjustable AC Power Source 0-300V 45-400Hz","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/CP70D50__1_2_20241023134049_1.pdf?v=1794474710\" rel=\"noopener\" style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" target=\"_blank\"\u003e \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" fill=\"currentColor\" viewbox=\"0 0 16 16\" style=\"margin-right: 8px;\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eIndustrial Control Equipment Testing with 5-20kVA\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan\u003eAdjustable AC Power Source 0-300V 45-400Hz\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eAdjustable AC Power Source for Industrial Control Equipment Testing\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5-20kVA Adjustable AC Power Source\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to provide adjustable AC power for industrial control equipment development, functional evaluation, and production testing. With adjustable output voltage and frequency, it allows engineers to establish different AC input conditions when evaluating compatible industrial control panels, electrical control cabinets, automation equipment, and other AC-powered industrial systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAvailable in four capacity options — 5kVA, 10kVA, 15kVA, and 20kVA — this single-phase input AC power source accommodates different testing power requirements. Its 7-inch color touchscreen, preset voltage and frequency settings, online parameter adjustment, power-off memory, and voltage ramp function support convenient operation in laboratory and industrial testing environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. Adjustable AC Output Voltage for Industrial Control Equipment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides adjustable AC output voltage for supplying compatible industrial control equipment during input power testing. Users can select the required voltage according to the rated input specifications of the control system or connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. Variable Frequency Output from 45–400Hz\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSupports adjustable output frequency within the specified operating range. This allows engineers to establish different AC input frequency conditions when evaluating compatible industrial control equipment designed for corresponding frequency requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Four Power Capacity Options: 5kVA to 20kVA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAvailable in 5kVA, 10kVA, 15kVA, and 20kVA configurations. Users can select a suitable capacity according to the power requirements of industrial control cabinets, automation equipment, and connected testing systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Support for Different Load Types\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe power supply supports resistive, inductive, capacitive, and rectifier loads. This provides flexibility for testing setups involving different types of compatible industrial electrical equipment, subject to the selected model's capacity and operating limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. 7-Inch Color Touchscreen\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 7-inch color touchscreen provides an operating interface for setting output parameters and viewing operating information. It displays voltage, current, power, frequency, and power factor, helping users monitor the AC power source during testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Preset Voltage and Frequency Settings\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUsers can preset output voltage and frequency parameters for repeated testing procedures. Online adjustment allows voltage and frequency settings to be changed during operation, while the power-off memory function retains the previous output mode and parameter settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. Voltage Ramp Function\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe voltage ramp function gradually increases the output voltage toward the selected setting. It can be used when evaluating how compatible industrial control equipment responds to a gradual change in its AC input voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. Multiple Protection Functions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe power supply provides overload, overcurrent, overvoltage, overheating, and short-circuit protection. When a protection condition occurs, an alarm and corresponding fault code are displayed to help users identify the event.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e9. Aging Impact Mode and SPWM Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe aging impact mode provides an operating option for applications involving power-on and power-off impact conditions. The system also uses high-frequency SPWM hardware adjustment and a high-power IGBT drive design as part of its power conversion and output control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. Industrial Control Cabinet AC Input Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides adjustable AC input power for compatible industrial control cabinets. Engineers can select suitable voltage and frequency conditions according to the input requirements of the control cabinet during inspection and evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. Industrial Automation Equipment Power Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSupplies adjustable AC power to compatible industrial automation equipment during laboratory evaluation. It can be used to establish selected input voltage and frequency conditions for equipment that requires an AC power source.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Electrical Control Panel Input Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides a controllable AC power source for evaluating compatible electrical control panels under selected input power conditions. Adjustable voltage and frequency settings support different testing requirements during development and verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. Industrial Control Equipment Development and Design Verification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides adjustable AC input power during the development and verification of industrial control equipment. Engineers can establish selected voltage and frequency conditions when evaluating equipment operation and power input compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Industrial Control Equipment Production Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCan be integrated into production testing setups where industrial control equipment requires an adjustable AC input source. Preset parameters and online adjustment support repeated power supply testing procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. Industrial Electrical Equipment Aging Evaluation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides AC power for compatible industrial electrical equipment aging evaluation setups. The voltage adjustment and aging impact mode can be incorporated into testing procedures involving specified power-on and power-off conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuality Check and Terms of Service:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEach unit is inspected before shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard accessories and product documentation are supplied according to the package configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlease confirm the required capacity, input power conditions, output voltage range, and installation requirements before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe 0–600V output is a customized option and must be confirmed before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlease select the appropriate capacity according to the power requirements of your industrial control equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm that the connected equipment is compatible with the selected output voltage and frequency conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact our customer support team if you need assistance confirming model specifications or product configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable AC Power Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Capacity Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5kVA \/ 10kVA \/ 15kVA \/ 20kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220V ±10% AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz ±5Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–300V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustomized Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–600V AC (Custom Option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Waveform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Sine Wave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported Load Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistive, Inductive, Capacitive, Rectifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Harmonic Distortion (THD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2% (Under Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCrest Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3:1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSource Effect\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Effect\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥85%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Setting Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Setting Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% of Reading + 0.5% of Full Scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Setting Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Setting Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Measurement Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Measurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% of Reading + 0.5% of Full Scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Measurement Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Measurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Measurement Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1A \/ 1A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Measurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% of Displayed Value + 0.5% of Rated Output Value)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Measurement Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1kW \/ 0.01kW \/ 0.001kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Measurement Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% of Reading + 0.5% of Full Scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-Inch Color Touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplayed Parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage, Current, Power, Frequency, Power Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eParameter Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnline Voltage and Frequency Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePreset Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage and Frequency Presetting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower-Off Memory for Previous Output Mode and Settings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Ramp, Aging Impact Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Frequency SPWM Hardware Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Power IGBT Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Overcurrent, Overvoltage, Overheating, Short Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFault Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm and Fault Code Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10°C to 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10%–90% at 25°C, Non-Condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Operating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eModel Selection and Dimensions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRated Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel 1 (5KVA)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530 × 430 × 592mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 50kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel 2 (10KVA)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e530 × 430 × 703mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 100kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel 3 (15KVA)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e580 × 478 × 950mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel 4 (20KVA)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e649 × 528 × 1020mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant Notes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAll four models in this product listing use single-phase AC input.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe standard output voltage is listed as 0–300V AC. The 0–600V AC configuration is a customized option and requires confirmation before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTHD ≤2% is specified under resistive load conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe 45–400Hz frequency range should be confirmed for the selected capacity before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eActual output current and available power depend on the selected model, output voltage, and load conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlease confirm that the industrial control equipment is compatible with the selected output voltage and frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlease confirm the required input current, wiring, and circuit breaker capacity before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommunication interfaces and protocols are not listed as standard features because their availability and configuration have not been confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose This 5-20kVA Adjustable AC Power Source?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial control equipment testing requires an appropriate AC power source to establish different voltage and frequency conditions during product development, input power evaluation, and production testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis adjustable AC power source combines variable voltage and frequency output, four capacity options, touchscreen operation, preset parameters, online adjustment, and practical voltage control functions in one system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhether used for industrial control cabinet testing, automation equipment evaluation, electrical control panel verification, or aging evaluation, it provides an adjustable AC power source for compatible industrial control equipment and related electrical systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"Model 1(5KVA)","offer_id":48178888573105,"sku":"CP70D50-1113-03","price":3849.0,"currency_code":"USD","in_stock":true},{"title":"Model 2(10KVA)","offer_id":48179101892785,"sku":"CP70D100-1113-03","price":6299.0,"currency_code":"USD","in_stock":true},{"title":"Model 3(15KVA)","offer_id":48179101925553,"sku":"CP70D150-1113-03","price":8999.0,"currency_code":"USD","in_stock":true},{"title":"Model 4(20KVA)","offer_id":48179101958321,"sku":"CP70D200-1113-03","price":11990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/Industrial_Control_Equipment_Testing_with_5-20kVA_Adjustable_AC_Power_Source_0-300V_45-400Hz-01.png?v=1794559246","url":"https:\/\/www.kuaiquinstrument.com\/products\/industrial-control-equipment-testing-with-5-20kva-adjustable-ac-power-source-0-300v-45-400hz","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}