Click the link above to get the full user guide for this product.
Series Parallel DC Power Supply for Railway Signal
Module Testing KUAIQU SPPS605-2KD 60V 5A
300W×2
Dual Channel Series Parallel DC Power Supply for Railway Signal Module Testing
The SPPS605-2KD Dual Channel DC Power Supply is designed to provide adjustable DC power for railway signal module testing, signal control equipment evaluation, and railway electrical circuit development. It features two independent output channels, each supporting 0–60V, 0–5A, and up to 300W, providing separate DC power conditions for compatible signal modules and electronic control assemblies.
Railway signal equipment may contain different DC-powered modules with specific voltage and current requirements. The SPPS605 supports Independent, Series, and Parallel output configurations to accommodate different test arrangements. Series Output provides up to 0–120V, 0–5A, and 600W, while Parallel Output provides up to 0–60V, 0–10A, and 600W.
Two versions are available: the SPPS605-2KD basic version and the SPPS605R-2KD programmable version with a communication interface. Both provide front-panel adjustment, 8-Group Memory, OCP and OVP protection, Output ON/OFF control, and one-key Series/Parallel switching. These features provide flexible DC supply options for railway signal module development, electrical inspection, and repeated bench testing.
Key Features
1. Independent Dual Channels for Separate Signal Modules
Each output channel provides adjustable DC voltage from 0–60V and current up to 5A, with a maximum power of 300W. The two independent channels allow engineers to establish separate power conditions for two compatible signal modules or two sections of a signal control circuit.
2. Series Output for Higher Voltage Signal Equipment
Series Output combines the two channels to provide up to 0–120V, 0–5A, and 600W. This configuration supports compatible railway signal modules and DC assemblies that require a higher voltage supply than a single channel can provide.
3. Parallel Output for Higher Current Requirements
Parallel Output provides up to 0–60V, 0–10A, and 600W. It offers a higher-current configuration for compatible DC signal equipment and electronic assemblies requiring greater current within the rated output range.
4. One-Key Series/Parallel Switching
The dedicated Series/Parallel mode button allows convenient switching between supported output configurations. A dedicated Series-Parallel Output Port provides a connection point for combined output configurations without complicated external wiring.
5. Fine Voltage and Current Adjustment
The precision encoder allows controlled output adjustment. With 10mV voltage setting resolution and 1mA current setting resolution, users can establish fine DC supply conditions for signal modules with different electrical ratings.
6. OCP and OVP Protection
Over Current Protection and Over Voltage Protection are available in Independent, Series, and Parallel output modes. These protection functions help reduce the risk of excessive current or voltage conditions during signal module power testing.
7. Independent Output ON/OFF Control
Dual Channel, Series, and Parallel modes support Output ON/OFF control. This allows users to manage output power during module connection, disconnection, and repeated test setup procedures.
8. 8-Group Memory for Signal Module Testing
The power supply provides eight memory groups:
-
CH1: 2 groups
-
CH2: 2 groups
-
Series Mode: 2 groups
-
Parallel Mode: 2 groups
Commonly used voltage and current settings can be stored and recalled for different signal module configurations and repeated electrical inspection procedures.
9. Negative-to-Zero-to-Positive Voltage Output
The power supply supports Negative Voltage–0–Positive Voltage output mode. This provides an additional polarity-related configuration for suitable signal module and DC circuit testing arrangements.
10. Panel Lock with Buzzer
The Panel Lock Function helps prevent accidental changes to configured output settings. The built-in buzzer provides an audible indication during operation.
11. Basic and Programmable Version Options
The SPPS605-2KD is the basic version with front-panel operation and memory functions. The SPPS605R-2KD is the programmable version with a communication interface for compatible communication-based control arrangements. Interface configuration should be confirmed before purchase.
Applications
Railway Signal Control Module DC Power Testing
Provides adjustable DC power for compatible railway signal control modules. Engineers can select the required voltage and current according to the module's rated input specifications during bench testing and electrical evaluation.
Railway Electronic Signal Circuit Testing
The two independent output channels can supply separate power conditions to compatible electronic signal circuits and control assemblies. This allows different modules or circuit sections to be powered independently during testing.
Signal Module Higher-Voltage Input Testing
The Series Output mode provides up to 120V and 5A for compatible signal-related DC modules that require a higher voltage input within the power supply's rated output range.
Railway Signal Equipment High-Current Testing
The Parallel Output mode provides up to 10A and 600W at a maximum output voltage of 60V. This configuration can supply compatible low-voltage signal modules or DC assemblies requiring higher current.
Signal Interface and Polarity Verification
The Negative Voltage–0–Positive Voltage output mode provides a polarity-related configuration for compatible signal circuit arrangements. External measuring instruments can be used to verify voltage polarity and connection conditions.
Dual Signal Module Comparison Testing
The independent CH1 and CH2 channels allow different power settings to be applied to two compatible signal modules. This is useful for comparing module input conditions and conducting separate electrical evaluation procedures.
Railway Signal Module Development and Bench Evaluation
The adjustable voltage and current settings, Series/Parallel output modes, and precision encoder adjustment provide flexible DC supply configurations during signal module development and engineering evaluation.
Repeated Signal Equipment Inspection
The 8-Group Memory Function allows frequently used voltage and current settings to be stored and recalled. Output ON/OFF control and Panel Lock support repeated bench testing and production inspection procedures.
Quality Check and Terms of Service:
-
Package includes: DC Power Supply ×1, Output Power Cord ×1, Input Power Cord ×1, User Manual ×1, and Warranty Card ×1.
-
The supplied product information states CE and FCC certification. Please confirm the applicable certificates for the selected version.
-
All DC power supplies and accessories are inspected before shipment.
-
Customer support is available for product configuration and technical questions.
-
Please confirm the signal module's rated input voltage, current, polarity, and power requirements before selecting an output mode.
-
Select the appropriate Independent, Series, or Parallel configuration according to the module specifications.
-
This power supply provides DC power for compatible railway signal equipment; railway signal safety certification and specialized signal-system diagnostics are not included as confirmed functions.
-
Please confirm the communication interface configuration when selecting the SPPS605R-2KD programmable version.
Technical Specifications
Output Ratings
| Parameter |
Specification |
| Product Model Options |
SPPS605-2KD Basic Version / SPPS605R-2KD Programmable Version |
| Product Type |
Dual Channel DC Power Supply |
| Independent Output |
0–60V, 0–5A, 300W × 2 |
| Series Output |
0–120V, 0–5A, 600W |
| Parallel Output |
0–60V, 0–10A, 600W |
| USB Output |
5V, 2A |
| Output Modes |
Independent, Series, Parallel |
| Output Control |
Output ON/OFF for Dual Channel, Series, and Parallel Modes |
| Series/Parallel Control |
One-Key Series/Parallel Mode |
| Series/Parallel Output Port |
Dedicated Output Port |
| Output Voltage Mode |
Negative Voltage–0–Positive Voltage |
Setting and Readback Specifications
| Parameter |
Specification |
| Voltage Setting Resolution |
10mV |
| Current Setting Resolution |
1mA |
| Voltage Readback Resolution |
10mV |
| Current Readback Resolution |
1mA |
| Voltage Setting Accuracy |
≤0.01% + 15mV |
| Current Setting Accuracy |
≤0.01% + 10mA |
| Voltage Readback Accuracy |
≤0.01% + 15mV |
| Current Readback Accuracy |
≤0.01% + 10mA |
Regulation and Ripple
| Parameter |
Specification |
| Load Regulation – Voltage |
≤0.3% + 10mV |
| Load Regulation – Current |
≤0.1% + 2.5mA |
| Line Regulation – Voltage |
≤0.01% + 2.5mV |
| Line Regulation – Current |
≤0.1% + 2.5mA |
| Voltage Ripple – Independent Mode |
≤200mVp-p, ≤25mVrms |
| Voltage Ripple – Series/Parallel Mode |
≤300mVp-p, ≤40mVrms |
| Current Ripple – Independent Mode |
≤20mArms |
| Current Ripple – Series/Parallel Mode |
≤35mVrms (as printed in the source specification; unit confirmation recommended) |
| Ripple Measurement Frequency Range |
20Hz–20MHz |
Response and General Specifications
| Parameter |
Specification |
| Rise Time – No Load |
≤200ms |
| Rise Time – Full Load |
≤300ms |
| Fall Time – No Load |
≤20s |
| Fall Time – Full Load |
≤300ms |
| Dynamic Response |
≤200ms |
| Efficiency |
≥85% |
| Input Voltage / Current |
110V / 8A; 220V / 5A |
| Protection Functions |
OCP, OVP |
| Memory Function |
8 Groups |
| Memory Allocation |
CH1: 2 Groups; CH2: 2 Groups; Series: 2 Groups; Parallel: 2 Groups |
| Panel Lock |
Yes, with Buzzer |
| Adjustment |
Precision Encoder Adjustment |
| Rated Operating Temperature |
0°C–40°C |
| Product Dimensions |
Approx. 24 × 12.5 × 13cm |
| Net Weight |
Approx. 2.75kg |
| Package Dimensions |
Approx. 38.5 × 23.5 × 20cm |
| Package Weight |
Approx. 3.4kg |
| Carton Quantity |
4 pcs/carton |
Version and Communication Options
| Version |
Description |
| SPPS605-2KD |
Basic version without communication-based programmable control; supports front-panel operation and 8-Group Memory |
| SPPS605R-2KD |
Programmable version with communication interface |
| Communication Interface Configuration |
USB / RS-232 / RS-485 options; confirm the actual interface configuration before ordering |
Important Notes:
-
Both versions share the listed SPPS605 electrical output ratings and front-panel functions.
-
Communication-based programmable control is available on the SPPS605R-2KD version, not the basic SPPS605-2KD version.
-
The available communication interface type should be confirmed before ordering.
-
Voltage resolution in the detailed specification table is 10mV, while current resolution is 1mA.
-
Confirm whether the required input version is 110V/8A or 220V/5A before ordering.
-
The Series/Parallel current ripple value is printed as ≤35mVrms in the source image. Confirm the unit with the manufacturer before publication.
Why Choose the SPPS605 Dual Channel DC Power Supply?
Railway signal module testing requires DC supply configurations that match the electrical requirements of different signal circuits and electronic control modules. The SPPS605 provides two independent 60V, 5A channels, allowing engineers to establish separate power conditions for compatible signal modules and test assemblies.
Its Series Output extends the available voltage to 120V, while Parallel Output increases the available current to 10A. These configurations provide additional flexibility when evaluating different DC-powered signal equipment.
With precision encoder adjustment, OCP and OVP protection, 8-Group Memory, Output ON/OFF control, and polarity-related output configuration, the SPPS605 supports repeatable bench testing and electrical evaluation. Users can choose between the basic SPPS605-2KD and the communication-based programmable SPPS605R-2KD according to their testing and control requirements.