The SPPS605-2KD Dual Channel DC Power Supply is designed to provide adjustable DC power for 48V telecom equipment testing, communication module evaluation, and DC power distribution development. It features two independent output channels, each supporting 0–60V, 0–5A, and up to 300W, making it suitable for establishing separate DC supply conditions for compatible telecommunications equipment and power modules.
For telecom devices requiring higher voltage or current configurations, the power supply provides one-key Series and Parallel Output modes. Series Output delivers up to 0–120V, 0–5A, and 600W, while Parallel Output provides up to 0–60V, 0–10A, and 600W. Its negative-to-zero-to-positive voltage output mode also provides an additional polarity-related configuration for suitable DC power testing arrangements.
Two versions are available: the SPPS605-2KD basic version without communication-based programmable control, and the SPPS605R-2KD programmable version with a communication interface. Both versions retain the dual-channel, Series/Parallel output configurations and front-panel operation functions. With precision encoder adjustment, OCP and OVP protection, Output ON/OFF control, and 8-Group Memory, this series provides flexible DC power options for telecom module evaluation and repeated bench testing.
Key Features
1. Dual Independent Outputs for 48V Telecom Equipment
Each independent channel provides adjustable output from 0–60V and 0–5A, with a maximum power of 300W per channel. This allows users to supply separate DC power conditions to two compatible telecom modules or establish independent test circuits within a telecommunications power system.
2. Series Output up to 120V
The Series Output mode combines the two channels to provide up to 0–120V, 0–5A, and 600W. It offers a higher-voltage configuration for compatible communication power modules and DC equipment that require an input voltage above the individual channel range.
3. Parallel Output up to 10A
The Parallel Output mode provides up to 0–60V, 0–10A, and 600W. This configuration is useful for compatible telecom power modules and DC loads that require higher current within the specified voltage range.
4. Negative-to-Zero-to-Positive Voltage Output
The power supply supports Negative Voltage–0–Positive Voltage output mode. This provides a polarity-related output configuration for compatible telecom power testing arrangements, including applications requiring different DC supply polarities. Actual connection and polarity settings should follow the equipment specifications.
5. Precision Voltage and Current Adjustment
The precision encoder allows controlled adjustment of output voltage and current. With 10mV voltage setting resolution and 1mA current setting resolution, users can establish fine DC supply conditions for telecom module input evaluation.
6. OCP and OVP Protection
Over Current Protection (OCP) and Over Voltage Protection (OVP) are available across Dual Channel, Series, and Parallel output modes. These functions help reduce the risk of excessive current or voltage conditions during telecom equipment power testing.
7. Output ON/OFF and One-Key Series/Parallel Switching
The Dual Channel, Series, and Parallel modes support Output ON/OFF control. A dedicated button allows convenient switching between Series and Parallel configurations, while the dedicated Series-Parallel Output Port simplifies connections without complicated external wiring.
8. 8-Group Memory for Repeated Telecom Testing
The power supply provides eight memory groups:
-
CH1: 2 groups
-
CH2: 2 groups
-
Series Mode: 2 groups
-
Parallel Mode: 2 groups
Frequently used voltage and current settings can be stored and recalled for repeated telecom module and DC power distribution testing.
9. Panel Lock with Buzzer
The Panel Lock Function helps prevent unintended changes to configured output settings. The built-in buzzer provides an audible indication during panel operation.
10. Basic and Programmable Version Options
The SPPS605-2KD is the basic version with front-panel operation and memory functions. The SPPS605R-2KD is the programmable version equipped with a communication interface. Please confirm the available interface configuration before ordering.
Applications
48V Telecom Power Module Testing
Provides adjustable DC power for evaluating compatible 48V telecom power modules. Users can set voltage and current conditions according to module input specifications and observe the power supply output readings during testing.
Communication Equipment DC Input Testing
Supplies DC power to compatible communication equipment and electronic modules. The independent output channels allow two separate devices or test circuits to receive different DC supply settings.
Negative-Polarity Telecom Power Testing
The Negative Voltage–0–Positive Voltage output mode provides a polarity-related configuration for suitable telecom equipment testing arrangements. Users should confirm the required polarity and wiring according to the equipment specifications before energizing the load.
Telecom Power Distribution Module Evaluation
The Series and Parallel modes offer different voltage and current configurations for compatible DC distribution modules and power assemblies. Series Output supports up to 120V, while Parallel Output supports up to 10A.
DC Backup Power Module Testing
Can serve as an adjustable DC source for evaluating compatible backup power modules and related communication equipment. External measuring instruments can be used to monitor additional electrical characteristics where required.
Dual Telecom Module Comparison Testing
The two independent output channels allow separate supply conditions to be established for two compatible telecom modules. This is useful for comparative electrical evaluation under different voltage and current settings.
Repeated Telecom Equipment Inspection
The 8-Group Memory Function, precision encoder adjustment, and Output ON/OFF control support repeated testing procedures with commonly used DC power settings.
Quality Check and Terms of Service:
-
Package includes: DC Power Supply ×1, Output Power Cord ×1, Input Power Cord ×1, User Manual ×1, and Warranty Card ×1.
-
The supplied product information states CE and FCC certification. Please confirm the applicable certificates for the selected version.
-
All DC power supplies and accessories are inspected before shipment.
-
Customer support is available for product configuration and technical questions.
-
Please confirm the telecom equipment's rated input voltage, current, polarity, and power requirements before selecting an output mode.
-
Select the appropriate Series or Parallel configuration according to the connected equipment specifications.
-
The SPPS605R-2KD programmable version requires confirmation of the communication interface configuration before ordering.
Technical Specifications
Output Ratings
| Parameter |
Specification |
| Product Model Options |
SPPS605-2KD Basic Version / SPPS605R-2KD Programmable Version |
| Product Type |
Dual Channel DC Power Supply |
| Independent Output |
0–60V, 0–5A, 300W × 2 |
| Series Output |
0–120V, 0–5A, 600W |
| Parallel Output |
0–60V, 0–10A, 600W |
| USB Output |
5V, 2A |
| Output Modes |
Independent, Series, Parallel |
| Output Control |
Output ON/OFF for Dual Channel, Series, and Parallel Modes |
| Series/Parallel Control |
One-Key Series/Parallel Mode |
| Series/Parallel Output Port |
Dedicated Output Port |
| Output Voltage Mode |
Negative Voltage–0–Positive Voltage |
Setting and Readback Specifications
| Parameter |
Specification |
| Voltage Setting Resolution |
10mV |
| Current Setting Resolution |
1mA |
| Voltage Readback Resolution |
10mV |
| Current Readback Resolution |
1mA |
| Voltage Setting Accuracy |
≤0.01% + 15mV |
| Current Setting Accuracy |
≤0.01% + 10mA |
| Voltage Readback Accuracy |
≤0.01% + 15mV |
| Current Readback Accuracy |
≤0.01% + 10mA |
Regulation and Ripple
| Parameter |
Specification |
| Load Regulation – Voltage |
≤0.3% + 10mV |
| Load Regulation – Current |
≤0.1% + 2.5mA |
| Line Regulation – Voltage |
≤0.01% + 2.5mV |
| Line Regulation – Current |
≤0.1% + 2.5mA |
| Voltage Ripple – Independent Mode |
≤200mVp-p, ≤25mVrms |
| Voltage Ripple – Series/Parallel Mode |
≤300mVp-p, ≤40mVrms |
| Current Ripple – Independent Mode |
≤20mArms |
| Current Ripple – Series/Parallel Mode |
≤35mVrms (as printed in the source specification; unit confirmation recommended) |
| Ripple Measurement Frequency Range |
20Hz–20MHz |
Response and General Specifications
| Parameter |
Specification |
| Rise Time – No Load |
≤200ms |
| Rise Time – Full Load |
≤300ms |
| Fall Time – No Load |
≤20s |
| Fall Time – Full Load |
≤300ms |
| Dynamic Response |
≤200ms |
| Efficiency |
≥85% |
| Input Voltage / Current |
110V / 8A; 220V / 5A |
| Protection Functions |
OCP, OVP |
| Memory Function |
8 Groups |
| Memory Allocation |
CH1: 2 Groups; CH2: 2 Groups; Series: 2 Groups; Parallel: 2 Groups |
| Panel Lock |
Yes, with Buzzer |
| Adjustment |
Precision Encoder Adjustment |
| Rated Operating Temperature |
0°C–40°C |
| Product Dimensions |
Approx. 24 × 12.5 × 13cm |
| Net Weight |
Approx. 2.75kg |
| Package Dimensions |
Approx. 38.5 × 23.5 × 20cm |
| Package Weight |
Approx. 3.4kg |
| Carton Quantity |
4 pcs/carton |
Version and Communication Options
| Version |
Description |
| SPPS605-2KD |
Basic version without communication-based programmable control; supports front-panel operation and 8-Group Memory |
| SPPS605R-2KD |
Programmable version with communication interface |
| Communication Interface Configuration |
USB / RS-232 / RS-485 options; confirm the actual interface configuration before ordering |
Important Notes:
-
The two versions share the stated SPPS605 output ratings and main front-panel functions.
-
The programmable communication functions belong to the SPPS605R-2KD version, not the basic SPPS605-2KD version.
-
The available communication interface type should be confirmed for the selected programmable version.
-
The detailed specification table lists 10mV voltage resolution and 1mA current resolution. The 1mV promotional wording shown elsewhere in the image is not used as the detailed voltage resolution.
-
Confirm whether the required input version is 110V/8A or 220V/5A before ordering.
-
The Series/Parallel current ripple unit is printed as mVrms in the source image and should be confirmed with the manufacturer before publication.
Why Choose the SPPS605 Dual Channel DC Power Supply?
48V telecom equipment testing requires a DC source that can establish different voltage and current conditions for communication modules and DC power assemblies. The SPPS605 provides two independent 60V, 5A channels, allowing separate DC supply conditions to be configured for compatible telecom equipment.
For applications requiring a different output configuration, Series Mode provides up to 120V and Parallel Mode provides up to 10A. The negative-to-zero-to-positive voltage mode adds polarity-related flexibility, while OCP and OVP protection, Output ON/OFF control, and 8-Group Memory support repeated bench testing.
The basic SPPS605-2KD and programmable SPPS605R-2KD versions give users a choice between front-panel operation and communication-based programmable control according to their testing requirements.