{"product_id":"kuaiqu-kq7901-test-fixture-integration-programmable-dc-power-supply-with-list-sequencing-remote-sense","title":"80V 20A 400W Test Fixture Integration Programmable DC Power Supply with List Sequencing \u0026Remote Sense KQ7901","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/KQ7901-_-20260514-1-23.pdf?v=1784628426\" target=\"_blank\"\u003e \u003csvg style=\"margin-right: 8px;\" viewbox=\"0 0 16 16\" fill=\"currentColor\" height=\"20\" width=\"20\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan\u003eKUAIQU KQ7901 80V 20A 400W  Test Fixture Integration \u003c\/span\u003e\u003cspan\u003eProgrammable \u003c\/span\u003e\u003cspan\u003eDC \u003c\/span\u003e\u003cspan\u003ePower Supply with List Sequencing \u0026amp; Remote Sense\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe KUAIQU KQ7901 Test Fixture Integration Power Supply is designed for test fixture developers, electrical test equipment manufacturers, and system integrators building customized electronic inspection platforms. Combining programmable DC output, a 4.3-inch TFT color display, five-digit voltage and current readouts, and real-time power monitoring, it provides a flexible power source for integrated test setups.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith local List sequence programming, USB data import, 100 configurable parameter memory groups, and USB, RS232, and RS485 communication interfaces, this programmable power instrument can be incorporated into compatible test fixtures and electrical measurement systems. Remote Sense compensation, reverse-polarity protection, OCP and OVP safeguards, and panel locking further support reliable operation in engineering test environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. Flexible Power Integration for Custom Test Fixtures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe KQ7901 provides programmable DC output for custom electronic test fixtures, interface-board verification platforms, and equipment development projects. Its digital controls and configurable output parameters allow integrators to establish suitable supply conditions for different devices under test, subject to the instrument's rated output range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e2. 4.3-Inch TFT Display for Instrument Panel Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 4.3-inch TFT color display presents voltage, current, power, and curve information in an accessible interface. Adjustable brightness supports different workbench and equipment environments, while Chinese and English language switching simplifies operation for engineering teams and equipment users.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e3. Five-Digit Readouts and Direct Parameter Entry\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFive-digit voltage and current displays, real-time power monitoring, rotary encoder adjustment, and numeric keypad entry provide convenient parameter configuration during fixture development and equipment commissioning. These controls help technicians configure supply settings when validating new test hardware or maintaining established test platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e4. 100 Memory Groups for Multiple Test Configurations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe KQ7901 stores up to 100 parameter groups, including voltage, current, OCP settings, and OVP settings. Integrators can organize suitable configurations for different test fixtures, board variants, and inspection procedures, reducing repeated manual setup when switching between supported test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e5. Local List Programming and USB-Based Sequence Import\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eList programming supports the creation of predefined output sequences directly on the instrument, while USB drive import allows compatible test data to be transferred into the power supply. This is useful when developing multi-step power application procedures for customized inspection fixtures and repeatable equipment demonstrations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConfirm supported file formats, sequence length, timing resolution, and transition behavior before implementing complex automated test routines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e6. USB, RS232, and RS485 Interfaces for System Communication\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMultiple digital interfaces provide options for connecting the KQ7901 to compatible computers, controllers, and test equipment. This flexibility supports instrument integration projects that require external parameter configuration or coordinated power control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eActual integration depends on the supported communication protocol, command set, software compatibility, and the control architecture of the host system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e7. Remote Sense Compensation for Fixture Wiring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eRemote Sense compensation helps account for voltage drops across output cables by sensing the voltage at the load connection. This can be valuable in test fixtures where wiring resistance affects the voltage reaching the device under test. Correct Sense connections and operation within the instrument's specifications are essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e8. Voltage, Current, and Power Curve Visualization\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe graphical interface can display two of the following parameters simultaneously: voltage, current, and power. This helps equipment developers observe output behavior during setup verification and troubleshooting, complementing measurements from external test instruments where required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e9. Reverse-Polarity Protection for Battery-Related Fixtures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in battery reverse-polarity protection triggers an alert when an incorrect battery connection is detected. This helps identify wiring mistakes in applicable battery-interface and protection-circuit test fixtures. Verify the supported connection method and battery testing requirements before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e10. OCP, OVP, Forced CV Mode, and Panel Lock\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOvercurrent protection and overvoltage protection provide additional safeguards during test equipment commissioning. Forced constant-voltage mode is designed to maintain CV operation under specified conditions, while panel locking helps prevent accidental changes to configured settings during fixture operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e11. Auxiliary USB-A and USB-C Charging Outputs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe USB-A and USB-C auxiliary outputs provide additional power options for compatible accessories and USB-powered devices used alongside the test setup. Real-time output monitoring helps users observe the auxiliary output status. Confirm supported charging protocols and output ratings before powering specific devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCustom Electronic Test Fixture Development\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProvide programmable DC power to custom fixtures designed for board-level verification, electronic assembly inspection, and repeatable functional checks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eATE System and Instrument Integration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntegrate the power supply into compatible automated test equipment architectures where programmable output, remote control, and repeatable parameter settings are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Inspection Equipment Manufacturing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSupport equipment manufacturers developing configurable inspection stations for electronic modules, control boards, and low-voltage assemblies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInterface Board and Controller Verification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSupply controlled DC power to interface boards, embedded controllers, and low-voltage control modules during fixture commissioning and system validation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMulti-Variant Test Station Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse stored parameter groups to organize supply settings for different product variants or fixture configurations, subject to the supported output range and test requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEngineering Test Platform Maintenance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUse the digital display, curve visualization, remote Sense capability, and communication interfaces to assist with power configuration, troubleshooting, and verification of integrated test platforms.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable class=\"ace-table\" style=\"width: 99.9589%; height: 490px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"200\" style=\"width: 35.8423%;\"\u003e \u003ccol width=\"200\" style=\"width: 35.8423%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EC2ffHZU1d6Nfhcs1fScRgVcnug\"\u003eParameter\u003c\/div\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JXHnfiiZPd1ls2cWTJqcKSiJnKq\"\u003eSpecification\u003c\/div\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NCzrfDfmQddOimc1pyzckmuTnVd\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TMk8fD51hdnSwxcWkWCcrRUinUh\"\u003eKQ7901-80-20\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MZs5fy0z2dJdCvcgDz6ceOA0nMg\"\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Q0ptfSZyzdb3yocy8JxcBdnjndd\"\u003e0 ~ 80V Continuously Adjustable\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XZq7fUGi8dutWUc5tPucfiaYnNf\"\u003e\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RxuLf3oyedLO8hcjITGcGonRnmf\"\u003e0 ~ 20A Continuously Adjustable\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KuwcfYm7vdcdLhcYcnKcy22nnvW\"\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SYiSfrqYyd0JkWcqogYcKsFnnCc\"\u003e400W\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZdYMf490PdHnOIc5Ho7cnh3Onub\"\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RENJfoe2fd62zcccEkscOxzBnWq\"\u003e5 mV rms, 30 mV p-p\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CAt9f0ycfdUQsYcHa6ucotPFnWb\"\u003e\u003cstrong\u003eVoltage Resolution (Setting \u0026amp; Readback)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IpiofbWE9dBj4NcZoLUcZleHnpd\"\u003e1 mV (0.001V)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-S6IVf4oMDdUoOXcgk5EczJR9ngh\"\u003e\u003cstrong\u003eCurrent Resolution (Setting \u0026amp; Readback)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GO6qfF1CQdWPx1clvJxcTRUYn4c\"\u003e1 mA (0.001A)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BlBZf04fBdFCi2cktyWc4wRRnpe\"\u003e\u003cstrong\u003ePower Readback Resolution\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XiJbfqhYVd372acQRKCcUwfOntg\"\u003e1 mW (＜ 100W); 10 mW (≥ 100W)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LTWnfxHYzdtc0AcchsGcx0lengf\"\u003e\u003cstrong\u003eDisplay Screen\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-C4KQfPmwsdhAvvclQuCcVVPHnsb\"\u003e4.3-inch 5-Digit HD Color Screen\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KN7rfqN8idgSJPcDudTcVsdjnLe\"\u003e\u003cstrong\u003eMemory Groups\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CP7yfZJRKdiiMvcOdzac6sYin6c\"\u003e100 Sets of Parameter Storage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Nu7lf1zFMdVZvLcbWd1ctBOuncz\"\u003e\u003cstrong\u003eProgramming Mode\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Tin9fw1PfdwBXPcOiNkcFW9cniE\"\u003ePanel Setting + USB File Import\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DSiKf9seZdEhZDcQx0TcQQMHnvf\"\u003e\u003cstrong\u003eWorking Mode\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JTQRfam91dvzGkc8oh8cMhtQnrc\"\u003eNormal Mode \/ Forced CV Mode\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NZ3Hfht57dbJx3cR0RNc2AqBngd\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HomrfHwRZdPAXDc3Pe4cQUBnnbe\"\u003eUSB, RS232, Optional RS485\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BtcLfk332drJm2czUlGcSt2knTh\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EFHNfRVD3d0B7icoACLcMfNgn7c\"\u003eModbus RTU\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.75px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 58.75px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PzXvf35PddZbzwcKCijcq89Wn6f\"\u003e\u003cstrong\u003eAdjustable Baud Rate\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 58.75px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Pbu4fpigYd6HTBcwRtKcZBM4nCe\"\u003e1200, 2400, 4800, 9600, 14400, 19200, 38400, 56000, 57600, 115200, 128000, 230400\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DhuufDlIPdiNrNcsEU8cFBZfnxd\"\u003e\u003cstrong\u003eFast Charge Ports\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Eftsf4TJKdWVHQckLytcHG6znBg\"\u003eUSB-A + USB-C Dual Ports\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 39.2045px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DDzyfEOYAdIMDScqmjic4fjgnfg\"\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 39.2045px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TTJBfyGQAdK4DecqmxncQ0KinNT\"\u003eOVP, OCP, OTP, Short Circuit Protection, Reverse Polarity Protection, Panel Lock\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ScjQfLSCWdKqJicOj2nciPp7nnc\"\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AuzkfEVbYdMgLvcccRjcoA9uneg\"\u003eIntelligent Temperature-Controlled Fan\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Tc0DfNfJZdUo4ocHdavck7cgndb\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-C0dsf5swhdiIA2cM8ncc62uensh\"\u003e110V \/ 220V AC Switchable\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-STIDf6RHldl9xmcFzYJcAqQwnHh\"\u003e\u003cstrong\u003eContinuous Operation\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LEPIfZtBLdKkxgcVpzFc5xCynxc\"\u003e24-hour Long-Term Stable Working Support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-G34OfoTDVdCmbPczCCTcdnDcnZr\"\u003e\u003cstrong\u003eDisplay Language\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\" style=\"height: 19.6023px;\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OAqTfSuBcd4usrc2Iwdc3S84nsd\"\u003eChinese \/ English Switchable\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"US Plug","offer_id":48032220119217,"sku":null,"price":899.0,"currency_code":"USD","in_stock":true},{"title":"EU Plug","offer_id":48032220151985,"sku":null,"price":899.0,"currency_code":"USD","in_stock":true},{"title":"UK Plug","offer_id":48032220184753,"sku":null,"price":899.0,"currency_code":"USD","in_stock":true},{"title":"AU Plug","offer_id":48032220217521,"sku":null,"price":899.0,"currency_code":"USD","in_stock":true},{"title":"JP Plug","offer_id":48032220250289,"sku":null,"price":899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/ade4a8f37a40c6e407365a8e20d6e7f4.png?v=1791965172","url":"https:\/\/www.kuaiquinstrument.com\/fr\/products\/kuaiqu-kq7901-test-fixture-integration-programmable-dc-power-supply-with-list-sequencing-remote-sense","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}