{"product_id":"analog-signal-conditioning-board-testing-with-r-sps1005-regulated-dc-supply-0-100v-0-5a-500w","title":"Analog Signal Conditioning Board Testing with R-SPS1005 Regulated DC Supply 0-100V 0-5A 500W","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/English_Manuel.pdf?v=1747883891\" rel=\"noopener\" style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" target=\"_blank\"\u003e \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" fill=\"currentColor\" viewbox=\"0 0 16 16\" style=\"margin-right: 8px;\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"header-iWP5WJ auto-hide-last-sibling-br\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/12.png?v=1776150334\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eAnalog Signal Conditioning Board Testing with \u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan\u003eR-SPS1005 Regulated DC Supply 0-100V 0-5A 500W\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eAdjustable 0–100V DC Supply for Analog Board Power-Up\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe NICE-POWER R-SPS1005 Regulated DC Supply provides an adjustable output voltage from 0 to 100V, with a maximum output current of 5A and rated output power of 500W. For Analog Signal Conditioning Board Testing, engineers can set the DC supply voltage according to the board's rated input requirements before powering up a prototype or assembled circuit. This helps establish a controlled power source for initial board checks and development work.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e500W Output for Signal Conditioning Circuit Development\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWith a rated output power of 500W, the R-SPS1005 can power compatible analog signal conditioning boards and related circuit modules within its voltage, current, and power limits. Typical bench tasks include powering sensor interface circuits, analog amplifier stages, and signal conditioning modules during prototype development. The connected device's input requirements must be checked before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCV\/CC Operation for Controlled Board Powering\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe power supply supports constant-voltage (CV) and constant-current (CC) operation, with automatic switching according to output and load conditions. CV operation is suitable when the circuit requires a specified DC supply voltage. CC operation can limit the output current under applicable load conditions, helping engineers manage power delivery while investigating unexpected current demand. These functions do not replace dedicated overvoltage protection, signal analysis, or circuit diagnostic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eVoltage, Current, and Power Display for Output Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe four-digit display presents output voltage and current readings, with power also displayed. During Analog Signal Conditioning Board Testing, engineers can monitor the power supply's output while applying the required DC input to the board. These readings describe the supply output; they do not directly measure sensor signals, amplifier gain, signal noise, or filter response.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFront-Panel Adjustment and Output ON\/OFF Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe encoder knob allows convenient front-panel adjustment of the output settings, while the output ON\/OFF control allows the DC output to be enabled or disabled as needed. This is useful when preparing a board for power-up, changing the supply setting between test steps, or switching off the output before modifying wiring or circuit connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFront and Rear Output Terminals for Bench Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe R-SPS1005 includes front and rear output terminals to accommodate different bench connection arrangements. The front output terminal is intended for currents below 5A, while the rear terminals can be used for full-power output with appropriate wiring and connections. Select the output terminals according to the required current and the manufacturer's connection instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eSensor Signal Conditioning Board Power-Up Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvide DC power to compatible sensor signal conditioning boards during prototype assembly and initial power-up. Engineers can set the required supply voltage and observe the power supply's output readings while checking whether the board starts up under the intended power conditions. Sensor output voltage, accuracy, and response must be checked with suitable measurement instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAnalog Amplifier and Filter Board Development\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003ePower analog amplifier boards, active filter circuits, and related signal conditioning stages during laboratory development. The adjustable DC supply helps engineers apply the specified operating voltage while testing the assembled board. Gain, bandwidth, cutoff frequency, distortion, and noise require separate signal-generation and measurement equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAnalog Input Interface Board Verification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSupply DC power to analog input interface boards used in measurement equipment, data acquisition systems, and industrial control interfaces. The R-SPS1005 can support board-level power checks during development and troubleshooting. It supplies DC power to the circuit and does not generate, process, or analyze the board's analog input signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIndustrial Signal Conditioning Module Troubleshooting\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUse the regulated DC supply when investigating power-related issues in compatible industrial signal conditioning modules. Engineers can apply the required input voltage and monitor the supply's output current and power readings during troubleshooting. Unexpected readings can indicate that further inspection is needed, but they do not independently identify a failed component or determine the condition of the signal path.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAnalog Circuit Prototype Evaluation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003ePower newly assembled analog conditioning circuits during design iterations, laboratory experiments, and board validation. The adjustable output provides a convenient DC source when the test plan requires different supply-voltage settings within the product's rated limits. Confirm the prototype's input-voltage range, polarity, grounding requirements, and expected current before applying power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eQuality Check and Terms of Service:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePackage Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e DC Power Supply × 1, Output Power Cord × 1, Input Power Cord × 1, User Manual × 1, Warranty Card × 1.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCertifications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Has passed CE \u0026amp; FCC Certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuality Inspection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e All DC power supplies and accessories are inspected before shipment to ensure good quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCustomer Support:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contact us with any questions, and we'll respond within 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR-SPS1005 \/ R-SPS1005-R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated DC Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Output Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–100V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConstant Voltage (CV) \/ Constant Current (CC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Regulation (Voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1% + 10mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Regulation (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1% + 2.5mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Regulation (Voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.01% + 2.5mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Regulation (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1% + 2.5mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Setting Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Setting Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Readback Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Readback Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Setting Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.05% + 10mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Setting Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.01% + 10mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Readback Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.05% + 10mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Readback Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.01% + 10mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Ripple (Peak-to-Peak)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤200mVp-p\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Ripple (RMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤20mVrms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Ripple\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤20mArms (20Hz–20MHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRise Time (No Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤150ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRise Time (Full Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤200ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFall Time (No Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤15s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFall Time (Full Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤50ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Response Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤20ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConversion Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥85%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFour-digit voltage\/current display with power display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput ON\/OFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustment Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEncoder knob adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront and rear output terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFront Output Terminal Use\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput current below 5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRear Output Terminal Use\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable for full-power output with suitable wiring and connections\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional; verify the selected model and configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C–40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 26.5 × 18.5 × 8cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 2.8kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose NICE-POWER R-SPS1005 for Analog Signal Conditioning Board Testing?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe NICE-POWER R-SPS1005 Regulated DC Supply combines a 0–100V adjustable output, 5A maximum output current, and 500W rated output power for laboratory and engineering applications. Its CV\/CC operation, output voltage and current readings, power display, and front-panel controls support practical DC power delivery during analog signal conditioning board development.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor engineers working with sensor interfaces, analog amplifiers, filter circuits, and industrial signal conditioning modules, this regulated DC supply provides a configurable power source for board-level testing and troubleshooting. It is intended for supplying DC power—not for directly measuring or analyzing analog signals—so dedicated test instruments should be used when evaluating signal quality and circuit performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eModel Configuration Note:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e R-SPS1005 is the standard manual-adjustment version. R-SPS1005-R is the programmable version. USB, RS232, and RS485 communication interfaces are optional; confirm the actual configuration before ordering and do not assume these interfaces are included as standard.\u003c\/span\u003e\u003c\/p\u003e\n\n","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"AC220V(±10%) \/ R-SPS1005","offer_id":48038865371313,"sku":"R-SPS1005-B-220V-1015-04","price":199.0,"currency_code":"USD","in_stock":true},{"title":"AC220V(±10%) \/ R-SPS1005-R","offer_id":48038865404081,"sku":"R-SPS1005-R-B-220V-1015-04","price":219.0,"currency_code":"USD","in_stock":true},{"title":"AC110V(±10%) \/ R-SPS1005","offer_id":48038865436849,"sku":"R-SPS1005-B-110V-1015-04","price":199.0,"currency_code":"USD","in_stock":true},{"title":"AC110V(±10%) \/ R-SPS1005-R","offer_id":48038865469617,"sku":"R-SPS1005-R-B-110V-1015-04","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/Analog_Signal_Conditioning_Board_Testing_with_R-SPS1005_Regulated_DC_Supply_0-100V_0-5A_500W-01.png?v=1792054551","url":"https:\/\/www.kuaiquinstrument.com\/fr\/products\/analog-signal-conditioning-board-testing-with-r-sps1005-regulated-dc-supply-0-100v-0-5a-500w","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}