0-300V 45-400Hz 15kVA 10kVA 5-20kVA Variable Frequency AC Power Source for Transformer Testing

$3,849.00
$3,849.00
S'il vous plaît, dépêchez-vous ! 10 laissé en stock
Model: Model 1(5KVA)
Total: $3,849.00
10 les clients regardent ce produit

Réductions en magasin

Spend $200+ for 5% OFF | $400+ for 8% OFF | $800+ for 10% OFF. Discounts will be automatically deducted at checkout.

Garantie de prix

We offer a 30-day price guarantee: if the price of your purchased item drops within 30 days, we will refund the price difference.

Retours gratuits

30-Day return and refund guarantee refer to our refund policy.
0-300V 45-400Hz 15kVA 10kVA 5-20kVA Variable Frequency AC Power Source for Transformer Testing

0-300V 45-400Hz 15kVA 10kVA 5-20kVA Variable Frequency AC Power Source for Transformer Testing

$3,849.00

0-300V 45-400Hz 15kVA 10kVA 5-20kVA Variable Frequency AC Power Source for Transformer Testing

$3,849.00
Model: Model 1(5KVA)

Download English Manual (PDF)

Click the link above to get the full user guide for this product.

0-300V 45-400Hz 15kVA 10kVA 5-20kVA Variable

Frequency AC Power Source for Transformer Testing

Adjustable AC Excitation Source for Transformer Testing and Evaluation

Transformer testing often requires a controlled AC source to energize the primary winding and establish specific input voltage and frequency conditions. The 5-20kVA Variable Frequency AC Power Source provides adjustable AC output for transformer development, energization evaluation, and production testing.

With an adjustable output voltage of up to 300V AC and a variable frequency range specified from 45Hz to 400Hz, this power source allows engineers to configure different input conditions for compatible transformers. It can be used as the AC excitation source in testing setups where external instruments monitor the transformer's secondary-side voltage and other electrical characteristics.

Available in four capacity options — 5kVA, 10kVA, 15kVA, and 20kVA — the series provides flexibility for different transformer testing requirements. A 7-inch color touchscreen, voltage and frequency presets, online adjustment, power-off memory, and voltage ramp function make it suitable for laboratory evaluation and transformer production environments.

Key Features

1. Adjustable Primary-Side AC Excitation

Supplies adjustable AC power to the primary winding of compatible transformers. Engineers can select the input voltage according to the transformer's rated primary voltage and establish controlled energization conditions during transformer evaluation.

2. Variable Voltage and Frequency for V/F Condition Evaluation

Allows independent adjustment of output voltage and frequency to establish different AC input conditions. This is useful when evaluating compatible transformers at different operating points. Engineers should follow the transformer's rated voltage-to-frequency requirements to avoid excessive core flux and potential magnetic saturation.

3. 45–400Hz Frequency Adjustment

Provides adjustable output frequency within the supported operating range. This is particularly useful for transformer evaluation procedures that require input frequencies other than the standard 50Hz or 60Hz, provided the transformer is designed for the selected frequency.

4. Four Power Ratings for Different Transformer Sizes

Available in 5kVA, 10kVA, 15kVA, and 20kVA models. Users can select a power capacity based on the transformer's rated apparent power, excitation requirements, and expected input current.

5. Standard Sine Wave Output

Provides a standard sine wave AC output for supplying compatible transformers. The specified total harmonic distortion is ≤2% under resistive load conditions, providing a reference specification for the power source. Actual waveform performance under transformer loads depends on the operating conditions and should be verified when required.

6. Voltage Ramp for Controlled Transformer Energization

The voltage ramp function gradually increases the output voltage toward the selected setting. It provides a controlled voltage rise during transformer energization and allows engineers to observe the transformer's response as the input voltage increases.

7. Real-Time AC Output Parameter Display

The 7-inch color touchscreen displays output voltage, current, power, frequency, and power factor. These readings help engineers monitor the electrical conditions supplied to the transformer during an evaluation procedure. They represent the power source's output parameters rather than direct measurements of transformer winding characteristics.

8. Preset Settings for Repeated Transformer Tests

Users can preset output voltage and frequency parameters and adjust them online during operation. The power-off memory function retains the previous output mode and parameter settings, helping maintain convenient setup conditions for repeated transformer testing procedures.

9. Protection Functions for Testing Operation

The power supply provides overload, overcurrent, overvoltage, overheating, and short-circuit protection. When a protection condition occurs, an alarm and corresponding fault code are displayed to help users identify the event.

Applications

1. Transformer Primary Winding Energization

Provides adjustable AC power to the primary winding of compatible transformers. Engineers can establish the required input voltage and monitor the transformer's energization behavior using appropriate external measuring instruments.

2. Transformer Input Voltage Variation Testing

Allows engineers to change the AC input voltage to evaluate transformer behavior under selected voltage conditions. This can be used during design verification and input voltage tolerance evaluation, provided the selected conditions remain within the transformer's specified operating limits.

3. Transformer Frequency Response Evaluation

Provides adjustable input frequency conditions for transformers designed to operate at different frequencies. Engineers can compare the transformer's secondary-side response under selected input frequencies using external voltage and electrical measuring instruments.

4. Transformer V/F Operating Condition Evaluation

Supports the establishment of different voltage and frequency combinations for compatible transformer evaluation. This is useful for examining operating conditions associated with different V/F ratios while observing the transformer with suitable external instruments.

5. Transformer Production Energization Testing

Can be integrated into transformer production testing stations as an adjustable primary-side AC supply. Preset voltage and frequency parameters help establish repeatable input conditions for routine energization and production inspection procedures.

6. Transformer Aging and Power Cycling Evaluation

Provides AC input power for compatible transformer aging evaluation setups. The aging impact mode offers an operating option for procedures involving specified power-on and power-off conditions, according to the testing requirements and equipment ratings.

7. Transformer Secondary-Side Voltage Observation

Can serve as the input power source in a transformer testing arrangement where external instruments are connected to the secondary side. Engineers can observe secondary voltage changes under selected primary-side input conditions using suitable measurement equipment.

Quality Check and Terms of Service:

  • Each unit is inspected before shipment.

  • Standard accessories and product documentation are supplied according to the package configuration.

  • Please confirm the transformer's rated capacity, primary voltage, rated frequency, and expected excitation current before ordering.

  • The 0–600V output is a customized option and must be confirmed before purchase.

  • Select the appropriate power supply capacity according to the transformer rating and expected startup or magnetizing current.

  • Confirm that the selected output voltage and frequency are compatible with the transformer's rated V/F requirements.

  • Use appropriate external measuring instruments for secondary voltage, winding resistance, turns ratio, insulation resistance, and other transformer-specific measurements.

  • Contact our customer support team if you need assistance confirming model specifications or product configuration.

Technical Specifications

Parameter Specification
Product Type Variable Frequency AC Power Source
Input Phase Single Phase
Rated Capacity Options 5kVA / 10kVA / 15kVA / 20kVA
Input Voltage 220V ±10% AC
Input Frequency 50/60Hz ±5Hz
Standard Output Voltage 0–300V AC
Customized Output Voltage 0–600V AC (Custom Option)
Output Frequency 45–400Hz
Output Waveform Standard Sine Wave
Supported Load Types Resistive, Inductive, Capacitive, Rectifier
Total Harmonic Distortion (THD) ≤2% (Under Resistive Load)
Crest Factor 3:1
Frequency Stability ≤0.1%
Voltage Stability ≤1%
Source Effect ≤1%
Load Effect ≤1%
Efficiency ≥85%
Voltage Setting Resolution 0.1V
Voltage Setting Accuracy ±(0.5% of Reading + 0.5% of Full Scale)
Frequency Setting Resolution 0.1Hz
Frequency Setting Accuracy ±0.05%
Voltage Measurement Resolution 0.1V
Voltage Measurement Accuracy ±(0.5% of Reading + 0.5% of Full Scale)
Frequency Measurement Resolution 0.1Hz
Frequency Measurement Accuracy ±0.05%
Current Measurement Resolution 0.1A / 1A
Current Measurement Accuracy ±(0.5% of Displayed Value + 0.5% of Rated Output Value)
Power Measurement Resolution 0.1kW / 0.01kW / 0.001kW
Power Measurement Accuracy ±(0.5% of Reading + 0.5% of Full Scale)
Display 7-Inch Color Touchscreen
Displayed Parameters Voltage, Current, Power, Frequency, Power Factor
Parameter Adjustment Online Voltage and Frequency Adjustment
Preset Function Output Voltage and Frequency Presetting
Memory Function Power-Off Memory for Previous Output Mode and Settings
Additional Functions Voltage Ramp, Aging Impact Mode
Control Technology High-Frequency SPWM Hardware Adjustment
Power Drive High-Power IGBT Drive
Protection Functions Overload, Overcurrent, Overvoltage, Overheating, Short Circuit
Fault Indication Alarm and Fault Code Display
Protection Rating IP20
Operating Temperature -10°C to 40°C
Operating Humidity 10%–90% at 25°C, Non-Condensing
Maximum Operating Altitude ≤2000m

Model Selection and Dimensions

Model Rated Capacity Dimensions Weight
Model 1 (5KVA) 5kVA 530 × 430 × 592mm Approx. 50kg
Model 2 (10KVA) 10kVA 530 × 430 × 703mm Approx. 100kg
Model 3 (15KVA) 15kVA 580 × 478 × 950mm 140kg
Model 4 (20KVA) 20kVA 649 × 528 × 1020mm 170kg

Important Notes:

  • All four models in this product listing use single-phase AC input.

  • The standard output voltage is listed as 0–300V AC. The 0–600V AC configuration is a customized option and requires confirmation before ordering.

  • THD ≤2% is specified under resistive load conditions.

  • The 45–400Hz frequency range should be confirmed for the selected capacity before purchase, particularly for the 20kVA model.

  • Actual output current and available power depend on the selected model, output voltage, and load conditions.

  • Transformer magnetizing current and energization inrush current should be considered when selecting the power supply capacity.

  • The transformer's rated voltage and frequency must be observed when setting output voltage and frequency. An unsuitable V/F ratio may cause excessive core flux and magnetic saturation.

  • This product provides adjustable AC excitation power. It does not independently measure transformer turns ratio, winding resistance, insulation resistance, or core and copper losses.

  • Please confirm the required input current, wiring, and circuit breaker capacity before installation.

  • Communication interfaces and protocols are not listed as standard features because their availability and configuration have not been confirmed.

Why Choose This 5-20kVA Variable Frequency AC Power Source?

A suitable AC excitation source is an important part of transformer development and testing. Engineers need to establish controlled primary-side voltage and frequency conditions before observing the transformer's secondary-side response and other electrical characteristics.

This variable frequency AC power source combines adjustable voltage, variable frequency, four capacity options, voltage ramp, preset parameters, and output parameter monitoring in one system.

From primary winding energization and V/F condition evaluation to transformer production inspection and aging procedures, it provides a flexible AC input source for compatible transformers and professional electrical testing setups.

Warranty

30-Day return and refund guarantee (Refer to our Refund Policy), 2-year warranty (only available for orders purchased directly from kuaiquinstrument.com), lifetime technique support by KUAIQU.

Please feel free to reach us with any concerns:

Email: kuaiquinstrument@163.com

We strive to reply to you within 24 hours.

Shenzhen Kuaiqu Electronic Co., Ltd. was founded in 2014 and is located in Shenzhen City, Guangdong Province. It is a scientific and technological enterprise integrating,production and sales. Specializing in the production of DC stabilized power supply, variable frequency power supply, switching power supply, program-controlled power supply and other 100 kinds of measuring teaching instruments and industrial special equipment.

We are committed to delivering premium products and exceptional customer service, striving to be your most reliable and intelligent assistant.

At KUAIQU, we are committed to providing our customers with the best value for their purchases. To ensure you always get the best price, we offer a 30-day price guarantee on all products purchased directly from kuaiquinstrument.com. This policy aims to give you confidence and peace of mind when shopping with us.

What is the 30-Day Price Guarantee?

Our 30-day price guarantee means that if you purchase a product from kuaiquinstrument.com and the price of that product drops within 30 days of your purchase date, you are eligible for a refund of the price difference of the products. (Prices are based on USD. No refunds will be given for price changes in other currencies due to exchange rate fluctuations.)

How Does the Price Guarantee Apply?

  • Eligibility: The price guarantee applies only to purchases made on kuaiquinstrument.com. Products purchased from other retailers or third-party sellers are not eligible.
  • Timeframe: The price drop must occur within 30 days of your original purchase date.
  • Product Match: The price guarantee applies to the same product (identical model, specifications, and condition).

How to Apply for a Price Difference Refund

If you notice that the price of a product you purchased from kuaiquinstrument.com has dropped within 30 days, follow these steps to apply for a refund of the price difference:

  • Documentation: Prepare your order number and proof of the price drop (such as a screenshot and link to the product page showing the reduced price).
  • Contact Us: Reach out to our customer support team at kuaiquinstrument@163.com. Include your order number, proof of the price drop, and a brief explanation of your request.
  • Verification: Our team will verify the price drop and your purchase details.
  • Refund Process: Once verified, we will process the refund for the price difference to your original method of payment. It typically takes 1-3 business days for you to receive the refund.

At KUAIQU, we strive to provide our customers with high-quality products and exceptional customer service. Our 30-day price guarantee is just one of the ways we ensure you get the best value for your investment. Shop confidently with KUAIQU, knowing that you are always getting the best deal available.

Thank you for choosing KUAIQU. If you have any questions or need further assistance, please do not hesitate to contact our customer support team at kuaiquinstrument@163.com.

Vous aimerez peut-être aussi

Produits récemment consultés