{"product_id":"programmable-ac-power-source-for-international-mains-testing-30-75kva-380v-3-phase-input-single-phase-output-45-400hz","title":"Programmable AC Power Source for International Mains Testing 30-75kVA 380V 3-Phase Input Single-Phase Output 45-400Hz","description":"\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #2c3e50; background-color: #f8f9fa; border-radius: 4px;\"\u003e\n\u003ch2 style=\"margin: 0 0 10px 0; font-size: 20px; color: #2c3e50;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/English_Manual_AC_Power_Source.pdf?v=1794810032\" rel=\"noopener\" style=\"color: #2980b9; text-decoration: underline; font-weight: bold; display: inline-flex; align-items: center;\" target=\"_blank\"\u003e \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" fill=\"currentColor\" viewbox=\"0 0 16 16\" style=\"margin-right: 8px;\"\u003e\n        \u003cpath d=\"M.5 9.9a.5.5 0 0 1 .5.5v2.5a1 1 0 0 0 1 1h12a1 1 0 0 0 1-1v-2.5a.5.5 0 0 1 1 0v2.5a2 2 0 0 1-2 2H2a2 2 0 0 1-2-2v-2.5a.5.5 0 0 1 .5-.5z\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M7.646 11.854a.5.5 0 0 0 .708 0l3-3a.5.5 0 0 0-.708-.708L8.5 10.293V1.5a.5.5 0 0 0-1 0v8.793L5.354 8.146a.5.5 0 1 0-.708.708l3 3z\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e Download English Manual (PDF) \u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #666; font-size: 14px;\"\u003eClick the link above to get the full user guide for this product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan\u003eProgrammable AC Power Source for International\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan\u003eMains Testing 30-75kVA 380V 3-Phase Input \u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan\u003eSingle-Phase Output 45-400Hz\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eAdjustable AC Power for International Voltage and Frequency Testing\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eElectrical products designed for international markets may need to operate under different mains voltage and frequency conditions. A product intended for one market may have different electrical input requirements from a product designed for another. For manufacturers and testing laboratories, being able to reproduce these supply conditions is an important part of product development and verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis programmable AC power source provides adjustable single-phase output from 0 to 300V AC and a frequency range of 45–400Hz. By changing the voltage and frequency settings, engineers can establish different steady-state AC supply conditions and evaluate whether their equipment operates according to its intended electrical specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe equipment uses a 380V three-phase four-wire input with protective earth and provides high-capacity single-phase output. Four models are available, rated at 30kVA, 45kVA, 60kVA, and 75kVA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith preset settings, online adjustment, power-off memory, and a standard sine-wave output, it offers a practical testing solution for manufacturers developing products for different international electrical markets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWide Voltage Range for International AC Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe standard output voltage range is 0–300V AC. This allows users to establish different voltage conditions for evaluating products designed for various AC input requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCustomized output up to 600V AC may be available upon confirmation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAdjustable Frequency from 45Hz to 400Hz\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe output frequency can be adjusted from 45 to 400Hz. This covers a wide range of steady-state AC frequency requirements and allows engineers to evaluate compatible products under different frequency settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eStandard Sine-Wave Output\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe source provides standard sine-wave output, with THD of ≤2% under resistive-load conditions. Voltage stability is ≤1%, and frequency stability is ≤0.1%, helping maintain consistent electrical conditions during testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConvenient Preset Settings\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUsers can preset output voltage and frequency before starting a test. This is useful when working with multiple products that have different rated input requirements or when returning to previously established test conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOnline Adjustment for Flexible Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOutput voltage and frequency can be adjusted while the source is operating. Engineers can change the supply conditions and observe how a connected product responds within the available adjustment range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMemory Function for Repeated Evaluations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe source remembers the previous output mode and parameters after power interruption. This helps reduce repeated setup work when testing products that require regularly used electrical settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eClear Measurements on a 7-Inch Touchscreen\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe color touchscreen displays voltage, current, frequency, power, and power factor. Technicians can monitor the electrical readings directly during testing and check the operating condition of the connected load.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMultiple Load Compatibility and Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe source supports resistive, inductive, capacitive, and rectifier loads. Protection functions include overload, overcurrent, overvoltage, overtemperature, and short-circuit protection. Fault conditions can trigger an alarm and display a corresponding fault code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eInternational AC Voltage Compatibility Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for checking whether electronic products operate correctly under different specified AC input voltage conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e50Hz and 60Hz Equipment Evaluation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCan provide adjustable frequency settings for testing products designed for different mains frequency requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHousehold Appliance Market Adaptation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides adjustable AC input conditions for evaluating compatible refrigerators, washing machines, air conditioners, and other household appliances intended for different markets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLighting Product International Certification Preparation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCan be used as an adjustable AC supply during internal electrical evaluations of LED lighting equipment and other electronic lighting products. Any formal certification testing must follow the applicable test standards and procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eElectrical Product Development and Validation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eUseful for engineering teams that need to check the input characteristics of prototypes and finished products before introducing them to different international markets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuality Check and Terms of Service\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, please confirm the electrical requirements of your target application, including input voltage, operating frequency, rated current, apparent power, and load characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe standard output range is 0–300V AC and 45–400Hz. Customized 0–600V AC output may be available upon confirmation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease note that adjustable voltage and frequency provide steady-state AC supply simulation. Applications requiring voltage dips, surges, transient disturbances, harmonic injection, or special programmable waveforms need additional technical confirmation before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe equipment requires a 380V ±10% AC three-phase four-wire input with protective earth. Please ensure that the installation site has a suitable power supply and that the electrical installation is designed for the selected model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOur support team can assist with model selection and configuration questions before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eModel Selection\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eModel 1 (30kVA)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eModel 2 (45kVA)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eModel 3 (60kVA)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eModel 4 (75kVA)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current at 120V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e375A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e625A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current at 240V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e187.5A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e312.5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L × W × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e76 × 60 × 106cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e87.5 × 65 × 112.5cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e112 × 80 × 130.5cm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e112 × 80 × 130.5cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eInput and Output Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380V ±10% AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree-Phase Four-Wire + Protective Earth\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60Hz ±5Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-Phase Standard Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–300V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustomized Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–600V AC (Optional Customization)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Waveform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Sine Wave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eOutput Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Stability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Harmonic Distortion (THD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤2% (Resistive Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCrest Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3:1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSource Voltage Effect\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Effect\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥85%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported Load Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResistive, Inductive, Capacitive, and Rectifier Loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eSetting and Measurement Accuracy\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% of Reading + 0.5% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% of Reading + 0.5% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1A \/ 1A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% of Displayed Value + 0.5% of Rated Output Value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1kW \/ 0.01kW \/ 0.001kW\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5% of Reading + 0.5% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eFunctions and Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-Inch Color Touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplayed Parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency, Voltage, Current, Power, and Power Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOnline Adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage and Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePreset Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePreset Output Voltage and Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRemembers Previous Output Mode and Parameters After Power Interruption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, Overcurrent, Overvoltage, Overtemperature, and Short-Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFault Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Signal and Fault Code Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0Ie \u0026lt; Iout ≤ 1.1Ie: Output Cut-Off After 15 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1Ie ≤ Iout ≤ 1.2Ie: Output Cut-Off After 5 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOptional Communication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eGeneral Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Protection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10°C to 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10%–90% RH at 25°C, Non-Condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Operating Altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose This Programmable AC Power Source?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWhen a product is developed for international markets, its electrical compatibility should not be judged under only one fixed supply condition. Engineers need a way to change voltage and frequency, monitor the connected equipment, and repeat tests using established settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis programmable AC source brings these functions together with four high-capacity model options. It gives manufacturers and laboratory teams a flexible way to carry out international AC input evaluations and prepare electronic products for different electrical operating environments.\u003c\/span\u003e\u003c\/p\u003e","brand":"Shenzhen Kuaiqu Electronic Co., Ltd","offers":[{"title":"Model 1(30KVA)","offer_id":48219861450929,"sku":"CP70TD300-1123-04","price":15690.0,"currency_code":"USD","in_stock":true},{"title":"Model 2(45KVA)","offer_id":48219861483697,"sku":"CP70TD450-1123-04","price":19990.0,"currency_code":"USD","in_stock":true},{"title":"Model 3(60KVA)","offer_id":48219861516465,"sku":"CP70TD600-1123-04","price":25690.0,"currency_code":"USD","in_stock":true},{"title":"Model 4(75KVA)","offer_id":48219861549233,"sku":"CP70TD750-1123-04","price":29990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/8027\/3329\/files\/Programmable_AC_Power_Source_for_International_Mains_Testing_30-75kVA_380V_3-Phase_Input_Single-Phase_Output_45-400Hz-01.png?v=1795415212","url":"https:\/\/www.kuaiquinstrument.com\/es\/products\/programmable-ac-power-source-for-international-mains-testing-30-75kva-380v-3-phase-input-single-phase-output-45-400hz","provider":"KUAIQU Instrument Store","version":"1.0","type":"link"}