Click the link above to get the full user guide for this product.
DC-DC Converter Testing with DC Bench
Supply KUAIQU 0-60V 0-10A 600W
R-SPS6010S with Precision Encoder
The KUAIQU R-SPS6010S is a 0–60V 10A 600W DC Bench Supply designed for DC-DC Converter Testing and power conversion development. A DC-DC converter can require different input voltage conditions during development and evaluation, so the adjustable 0–60V output allows engineers to establish different DC input conditions within the rated range instead of working from a fixed supply voltage.
During converter testing, the R-SPS6010S provides direct voltage, current, and power readback through its four-digit display, while the Precision Encoder allows controlled adjustment of output parameters. M1-M3 memory presets can be used for repeated test conditions, and OCP, OVP, and Panel Lock help maintain controlled test operation.
Key Features
0-60V 0-10A 600W DC Bench Supply
The R-SPS6010S provides a 0–60V adjustable output, up to 10A current, and 600W maximum power. This output range gives engineers flexibility when establishing different DC input conditions for DC-DC converter testing.
Adjustable Input Conditions for DC-DC Converters
DC-DC converter evaluation may require testing at different input voltage levels. The adjustable DC output allows users to change the supply voltage according to the selected converter test condition within the rated operating range.
Precision Encoder for Controlled Adjustment
The Precision Encoder provides convenient adjustment of voltage and current settings. This is useful when converter testing requires gradual changes to the DC input condition or repeatable parameter adjustment.
Real-Time Voltage, Current, and Power Display
The four-digit display shows voltage, current, and power during operation. These readings allow engineers to observe the electrical input conditions of the converter while changing or maintaining the test parameters.
M1-M3 Memory for Repeated Converter Tests
Three memory groups, M1-M3, allow frequently used voltage and current settings to be stored and recalled. This can simplify repeated DC-DC converter tests when several predefined input conditions need to be applied.
OCP Protection for Controlled Converter Testing
Over Current Protection provides an additional protection function when the converter or connected test circuit draws excessive current. This helps keep the DC power source and test setup under controlled operating conditions.
OVP Protection for DC Input Testing
Over Voltage Protection helps protect the power supply and connected test setup when an over-voltage condition occurs. This is useful when different input voltage conditions are applied during DC-DC converter evaluation.
Output ON/OFF Control
The Output ON/OFF function allows users to start or stop the DC output while retaining the configured parameters. This can simplify repeated converter connection and testing procedures.
Panel Lock for Repeatable Test Conditions
The Panel Lock Button helps prevent unintended changes to voltage and current settings during testing. Once the required converter input condition has been established, the panel can be locked to help maintain the selected parameters.
Front and Rear Output Connections
The R-SPS6010S provides front and rear output connections for different bench and laboratory configurations. The front output is intended for applications below 5A, while the rear output can be used at the full rated output.
USB and Optional RS232/RS485 Communication Interfaces
The R-SPS6010S includes a standard USB port, with RS232/RS485 available as optional communication interfaces. These interfaces provide connection options for compatible DC-DC converter testing environments and external equipment.
Applications
DC-DC Converter Testing
Provide an adjustable DC input source for evaluating DC-DC converters under different input voltage and current conditions within the power supply's rated range.
DC-DC Converter Input Testing
Change the DC input voltage supplied to the converter to evaluate its operation under different selected input conditions.
Converter Operating Condition Testing
Provide different adjustable DC supply conditions while monitoring voltage, current, and power at the converter input during laboratory testing.
DC-DC Converter Prototype Evaluation
Use the R-SPS6010S as a DC Bench Supply during early-stage converter development and prototype evaluation, where different input conditions may need to be tested.
Power Conversion Circuit Testing
Provide adjustable DC power for compatible power conversion circuits and converter-related test setups that require controlled DC input conditions.
Converter Input Voltage Testing
Use the 0–60V adjustable output to establish different input voltage conditions for DC-DC converter evaluation within the converter's specified input range.
Converter Current Condition Testing
The up to 10A output capability provides a DC source for converter tests that require higher input current within the rated output capability of the R-SPS6010S.
Repeated DC-DC Converter Testing
Use M1-M3 memory presets to store frequently used voltage and current conditions and recall them when repeating converter tests under predefined conditions.
DC-DC Converter Development Testing
The Precision Encoder, adjustable output, real-time electrical readback, and protection functions provide a practical DC Bench Supply setup for converter development and laboratory verification.
Laboratory Power Conversion Testing
The R-SPS6010S combines adjustable DC output, Precision Encoder adjustment, four-digit voltage/current/power display, memory presets, OCP, OVP, Output ON/OFF control, and Panel Lock for laboratory DC-DC converter testing.
Quality Check and Terms of Service:
-
Package includes: DC Power Supply *1, Output Power Cord *1, Input Power Cord *1, User Manual *1, Warranty Card *1.
-
Has passed CE & FCC Certification.
-
All DC power supplies and accessories are inspected before shipment to ensure good quality.
-
Customer support: Contact us with any questions, and we'll respond within 24 hours.
Technical Specifications
| Parameter |
Specification |
| Model |
R-SPS6010S |
| Product Type |
DC Bench Supply |
| Output Voltage |
0-60V |
| Output Current |
0-10A |
| Rated Power |
600W |
| Voltage Setting Resolution |
10mV |
| Current Setting Resolution |
10mA |
| Voltage Readback Resolution |
10mV |
| Current Readback Resolution |
10mA |
| Voltage Setting Accuracy |
≤0.05% + 10mV |
| Current Setting Accuracy |
≤0.01% + 10mA |
| Voltage Readback Accuracy |
≤0.05% + 10mV |
| Current Readback Accuracy |
≤0.01% + 10mA |
| Voltage Load Regulation |
≤0.1% + 10mV |
| Current Load Regulation |
≤0.1% + 2.5mA |
| Voltage Line Regulation |
≤0.01% + 2.5mV |
| Current Line Regulation |
≤0.1% + 2.5mA |
| Voltage Ripple |
≤400mVp-p / ≤60mVrms |
| Current Ripple |
≤20mArms |
| Rise Time, No Load |
≤150ms |
| Rise Time, Full Load |
≤200ms |
| Fall Time, No Load |
≤15s |
| Fall Time, Full Load |
≤50ms |
| Dynamic Response |
≤20ms |
| Efficiency |
≥85% |
| Memory Presets |
M1-M3, 3 Groups |
| Protection |
OCP, OVP |
| Display |
Four-Digit Voltage, Current, and Power Display |
| Output Control |
Output ON/OFF |
| Communication Interface |
Standard USB, Optional RS232/RS485 |
| Output Connections |
Front and Rear |
| Front Output Rating |
Below 5A |
| Rear Output |
Full Rated Output |
| Operating Temperature |
0°C–40°C |
| Dimensions |
Approx. 26.5 × 19 × 8.5 cm |
| Net Weight |
Approx. 2.5 kg |
Why Choose KUAIQU R-SPS6010S?
The KUAIQU R-SPS6010S provides the adjustable DC input conditions needed for many DC-DC Converter Testing setups. Its 0–60V output range and up to 10A current capability allow engineers to establish different input conditions within the converter and power supply ratings, while the 600W output capacity supports compatible medium-power converter test setups.
The Precision Encoder makes voltage and current adjustment convenient when changing converter input conditions. At the same time, the four-digit display provides direct voltage, current, and power readings, allowing engineers to observe the electrical input conditions during testing.
For repeated converter evaluation, M1-M3 memory presets provide three groups of stored settings for frequently used test conditions. OCP and OVP add protection functions to the test setup, while Output ON/OFF control and Panel Lock help make repeated parameter setup and operation more controlled.
With its DC Bench Supply form, 0–60V adjustable output, 10A current capability, 600W rated power, Precision Encoder, memory presets, four-digit monitoring display, and protection functions, the R-SPS6010S provides a flexible DC power source for DC-DC Converter Testing, converter input testing, prototype evaluation, and laboratory power conversion testing.